ILSL 33/44 Owner‘s Manual
Rev.1.1
30
Liftgate
Mount Frame
2Ga Power Cable
From Liftgate (+)
Ground Cable
From Liftgate (-)
**Resetable
Circuit
Breaker
Single
Pole
Socket
*In-Line
Fuse
Wires #2 and #4
go to postitive (+)
4-Conductor
Power Cable
from Control Board
Wires #1 and Gr/Yl
go to ground (-)
Aux.
Batteries
***Ground
*In-Line ATC Fuse: 20 Amp.
Replace with same amperage fuse when necessary.
**Resetable Circuit Breaker: 150 Amp Min.
Replace with same amperage breaker when necessary.
***Ground: For optimal grounding, ground all batteries and power units to the body side rails of the vehicle.
NOTICE: DO NOT attempt to jump in-line fuses with other objects other than the specified fuse.
DO NOT increase the amperage rating of fuse. Serious harm to the liftgate will result when
standard practices are not followed.
Single Pole Plug Charging System