Note 1: The default value for the United Kingdom is (LN / TT, TN-S, TN-
C-S) Fig.3.
•
Note 2: If your installation is not covered by the above standard grid types,
please contact Lewden Ltd. for further assistance and confirmation.
•
Note 3: United Kingdom wiring regulations BS7671: 2018 section 722
prohibit circuits supplying charge equipment for electric vehicles to
include a PEN conductor (TN-C-S earth arrangement), where the charging
point is located outdoors, or is reasonably expected to be used to charge
a vehicle that is located outdoors.
To overcome this, the local earthing arrangement at the EV charger must
be converted to a TT arrangement by the installation of a separate earth
electrode, or alternatively, the installation must incorporate a protective
device which guards against an open circuit PEN conductor fault.
Reference should be made to BS7671 for further guidance.
Switch 1 (Power Grid Type)
Switch 2 (Grounding System)
ON
LN
IT
OFF
LL
TT / TN-S / TN-C-S
120V
120V
208V
PE
L1
L2
V/2
V/2
V
PE
L1
L2
0
V
V
PE
L
N
V=240 or 200 volt
EVSE
input Connector
EVSE
input Connector
EVSE
input Connector
V=240 or 230 or 220 or 200 volt
Fig.1
Fig.2
Fig.3
• For dip switch location see A on page 13 of this manual
A
Green Power, Green Lifestyle.
12
Summary of Contents for Lewden ASPEN Series
Page 1: ......