5.3 RECOVERY OF THE PERSONNEL ON THE AERIAL CAGE
Machine working in order.
It is possible to recovery personnel on the aerial cage acting on the ground
controls: turn key (Fig. 3.2 pos. 1) on turntable symbol and operate by the remote
control; in this case you can working because all the safety devices work regularly
Anomaly to the electric plant
In case of motor and pump doesn’t run, it is impossible to act on ground control
panels, or there is an anomaly to the electric plant.
To lower the aerial cage on ground, act as follow:
•
Inside to the turntable, uncover in lead and unscrew the blue cap of the valve
marked with EV09 (fig. 5.1 part.1) and EV23 (Fig.5.2), push the cursor and
rotate in clockwise and lock in that position.
•
Open the cover of Fig. 5.3
Fig.
5.1
Fig.
5.2
•
Telescopic boom in.
By means the lever 1 of Fig. 5.4 activate the boom in
(see the label).
•
Lowering main boom.
Once the telescopic boom is total in, with the lever 2
of Fi. 5.4 activate the lowering boom (see the label) until the cage is on the
ground.
•
Attention!
During the lowering boom, the cage not levelling automatically
but it’s necessary to do this manually as follow: push the button of the valve
in the turntable marked with EV10(Fig. 5.1 part. 2) and at same time, the
person on the cage has to push the centre of the valve of Fig. 5.5 from one
side or other until the cage floor is horizontal. Execute alternatively the cage
levelling and boom lowering.
1
2
Summary of Contents for RAGNO XTJ 32 / C
Page 65: ...Palazzani Palazzani Industrie spa OM 201 Pag 1 Cap 2...
Page 66: ...Palazzani Palazzani Industrie spa OM 201 Pag 2 Cap 2...
Page 106: ...Palazzani Palazzani Industrie spa OM 401 pag 1 Cap 4...
Page 112: ...Palazzani Palazzani Industrie spa OM 564 pag 6 Cap 5...
Page 114: ...Palazzani Palazzani Industrie spa OM 564 pag 8 Cap 5 Fig 5 10 Fig 5 11...
Page 153: ...Palazzani Palazzani Industrie spa OM 801 pag 1 Capp 8 11...
Page 161: ......
Page 162: ......
Page 167: ......
Page 168: ......
Page 171: ......
Page 174: ......
Page 176: ......
Page 178: ......
Page 182: ......
Page 183: ......
Page 185: ......
Page 187: ......
Page 189: ......
Page 191: ......
Page 193: ......
Page 194: ...VARIANTE CON STABILIZZATORI A BRACCIO FISSO OPZIONALE...
Page 199: ......
Page 201: ......
Page 204: ......