Page 7
Kore 7th Manual / kHLab Edition
USB
Port for Firmware upgrade.
DC pump
Port for DC pump (ATO refill pump).
Optical sensor
Connection port for optical sensor (used for ATO/AWC).
Temp sensor
Digital temperature sensor port.
Floating sensors port
Not used in newest version of software/firmware and designed
for future applications.
Antenna port
External Wi-Fi antenna port.
Required for proper work!
Reset button
Hardware reset switch (short push generate reset signal to
main CPU).
Power supply port
Required 12V 1A/2A power supply with 2.1mm plug.
kHLab Digital I/O port
Used for connection
kHLab Module
or Magnetic Stirrer, DC
AWC pump etc.
pH #1
Connection port for pH probe nr 1 (kHLab module).
pH #2
Connection port for pH probe nr 2 (Calcium Reactor).
Important!
1. Make sure that a water mixing magnetic stirrer bar/pellet is put inside
kHLab module test cylindrical chamber.
2. Make sure to connect silicone tubing properly to individual Kore 7th
dosing pumps:
– Pump nr 1 -
supplies
water
sample
(aquarium water)
to kHLab
test chamber. Do NOT exceed 100cm (39”) length between the
place of taking test water and the kHLab device.
– Pump nr 2 -
supplies
reagent solution
for testing. Try to place
the reagent solution bottle as close as possible to the doser and
at a similar level.
– Pump nr 3 -
removes
waste water
(tested water)
from the
kHLab test chamber. This water can be drained to aquarium (we
suggest near the pump sucking in water to the protein skimmer).
The length of the silicone tubing from the pump outlet should not
exceed 150cm (59”).
3. Make sure to connect the control cable between the kHLab device
and the Kore 7th dosing station.