SYSTEM COMMAND TABLE
S-Cmd
Command Description
and Data Format
Read Back
Syntax
Command
Syntax
Factory
Setting
Stored
Location
00
No Operation
Used for clearing a macro area
N/A 00
N/A
N/A
01
System mode
Mode 0 = System off, 1 = COS, 2 = Rpt CTCSS/DCS,
3 = COS + Rpt CTCSS/DCS, 4 = Open squelch,
5 = Rpt audio off, 6 = PTT and repeat audio Off
7 = Rpt audio off, RX audio disabled when PTT active.
01 01
[Mode]
3
COS+
CTCSS
RAM
EEPROM
02
RX Audio source mode
Mode 0 = Pass sub audio, 1 = Reject sub audio
02 02
[Mode]
1
Reject sub
audio
RAM
EEPROM
03
Control Prefix Set up
Item 0 = Function Mode
Data 0 = Disable, 1 = Lockout, 2 = Local port,
3 = Link port
Item 1 = Prefix, 1-4 DTMF characters
Data = All DTMF characters
Item 2 = Aux Mute Character
Data = 0 (Disable), 1-9, 10-15 (A-D, *, #), 16 (0)
Item 3 = Command timer
Data = 25-255 in 100ms inc.
Item 4 = Active telemetry tone
Data = Four sets of 3 digit tone commands
Item 5 = Busy telemetry tone
Data = Four sets of 3 digit tone commands
03 [Item]
03 [Item] [Data]
Item 0
0 (Disable)
Item 1
No prefix
Item 2
0 (Disable)
Item 3
80 (8.0 S)
Item 4
026 079
272 000
Item 5
028 079
293 329
RAM
EEPROM
04
Repeater carrier delay time
Time = 0 to 255 in 1/10 second increments
04
04
[Time] 30
3.0 Sec
RAM
EEPROM
05
Force on repeater PTT for set time
Time = 0 to 3600 second
05
05
[Time] 0
Sec.
Power
On
06
Repeater telemetry mode
Mode 0 = Disable, 1 = Suppress function complete/error
one time, 2 = CW ID only, 3 = CW & Speech ID only,
4 = CW function complete & ID only,
5 = CW & Speech function complete & ID only,
6 = CW only, 7= All on
06 06
[Mode]
7
All on
RAM
EEPROM
07
ID interval time
Time = 0 to 255 in 6 seconds increments, 0 = disable
07 07
[Time] 10.0
Min.
RAM
EEPROM
08
Courtesy message timer, COS falling to start of message
Time = 0 to 99 in 1/10 second increments, 0 = disable
08
08
[Time] 1.5
Sec.
RAM
EEPROM
09
LED Status Display (lowers current drain)
Mode 0 = Disable (off), 1 = Enable (on)
09 09
[Mode]
1
on
RAM
EEPROM
10
Repeater time-out time
Time = 0 to 255 in 6 seconds increments,
0 = disable, * = Reset timer
10
10
[Time] 0
0.0 Min.
RAM
EEPROM
11
Alternate command terminator
Terminate 0 = None (COS Only), 1-4 = A-D, 5 = *, 6 = #,
7 = Inter-digit timer, 8 = Min 1 digit cmds, 9 = Min 2 digit
cmds, 10 = Min 3 digit cmds, 11 = Min 4 digit cmds, 12 =
Min 5 digit cmds, 13 = Min 6 digit cmds, 14 = Min 7 digit
cmds, 15 = Min 8 digit cmds
11 11
[Terminate] 7
Inter-digit
RAM
EEPROM
12
Transmit audio output adjust
Adj. = 0 to 63 or * up one count, # down one count
12 12
[Adj]
31
RAM
EEPROM
13 DAC
output
DAC 1 & 2, Output 0-255 (0 = 0 volts, 255 = 5 volts)
13
13 [DAC] [Output]
0
RAM
EEPROM