Pacific Research Solutions
RI-300e User Manual
Page 84
S-Cmd 63
MACRO EDITOR, SET STARTING LINE NUMBER POINTER
Macros are one or more S-Commands strung together. Messages are also stored in the same memory area as macros. To build
a macro or message, you must first tell the controller where the macro or message will start (Macro Start Line). Then enter
S-Commands (S-Command 64) or CW-Commands (S-Command 31) into the macro data memory. This command is used to set
the macro start line pointer. The controller will keep track of the exact position in the macro data memory as you enter data.
There are 999 starting lines in the macro data memory.
SYNTAX: 63 [Macro start line]
READ
BACK
N/A
STORAGE:
RAM
PARAMETERS: Macro start line 000 through 999
DEFAULT:
N/A
EXAMPLE: 63 7 Sets the pointer to start on line number 7
S-Cmd 64
MACRO EDITOR, INSERT S-COMMANDS
The system memory is used for both macros and messages. This memory is organized with 999 lines of data storage with each
line consisting of 24 digits. Once you have set the macro start line pointer (S-Command 63), you can begin to enter
S-Commands into the macro data memory. One or more S-Commands can be strung together and the data is allowed to
continue through additional lines until the end of the macro is reached. When you enter S-Commands and their date into
memory, the controller will add a “C” so as to separate the S-Commands. It is important to know how the controller stores
data, so that you can allow for this digit when keeping track of memory usage. The last entry of your macro is an end of macro
character, “D” which is used to terminate the macro. Send “64” without data, and the controller will put a “D” into the macro
data memory for you. The controller uses a “C” for a command separator and “D” for end of macro. You need to allow space
for these digits when planning your macro data usage. See the default table below for an example.
SYNTAX: 64 [S-Command] [S-Command data]
READ
BACK
N/A
STORAGE:
EEPROM
PARAMETERS: S-Command 00-99
S-Command data as required by each command
DEFAULT: Start line 001 067C 340C D . . . . . . . . . . . . . . . . . . . . . .
System reset, power on
Start line 002 010C D . . . . . . . . . . . . . . . . . . . . . . . . . . .
System off
Start line 003 011C D . . . . . . . . . . . . . . . . . . . . . . . . . . .
System on, COS access
Start line 004 013C D . . . . . . . . . . . . . . . . . . . . . . . . . . .
System on, CTCSS/DCS + COS
Start line 005 014C D . . . . . . . . . . . . . . . . . . . . . . . . . . .
System on, open squelch
Start line 006 1811C D . . . . . . . . . . . . . . . . . . . . . . . . . .
Repeater mute on
Start line 007 1810C D . . . . . . . . . . . . . . . . . . . . . . . . . .
Repeater mute off
Start line 008 0430C D . . . . . . . . . . . . . . . . . . . . . . . . . .
Carrier delay on
Start line 009 040C D . . . . . . . . . . . . . . . . . . . . . . . . . . .
Carrier delay off
Start line 010 222C D . . . . . . . . . . . . . . . . . . . . . . . . . . .
PL Encode on
Start line 011 220C D . . . . . . . . . . . . . . . . . . . . . . . . . . .
PL Encode off
Start line 012 061C 821C 065C 1510C D . . . . . . . . . . . . Telephone off-hook
Start line 013 067C 820C 1511C D. . . . . . . . . . . . . . . . .
Telephone on-hook
Start line 014 80C D . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flash Hook
Start line 015 061C 829C 1510C D . . . . . . . . . . . . . . . . . Answer a ringing telephone
Start line 016 343C 35111C A1343C A135111C D . . . . . Link on
Start line 018 340C A1340 C D . . . . . . . . . . . . . . . . . . . . Link off
EXAMPLE: 64 01 1
S-Command 01 (repeater mode), S-Command data 1 (COS)
64 02 1
S-Command 02 (sub audio filter), S-Command data 1 (on)
64
End of macro
This macro will both set the repeater in COS and enable the sub audio filter.
The data will be stored in memory the following format (011C 021CD)
Summary of Contents for RI-310e
Page 2: ......
Page 34: ......
Page 91: ......
Page 142: ...Pacific Research Solutions RI 300e User Manual Page 134 ANALOG CIRCUIT BOARD SCHEMATIC...
Page 146: ...Pacific Research Solutions RI 300e User Manual Page 138 CPU BOARD SCHEMATIC...