FOR ASSISTANCE CALL 1-800-275-6187
10.11
Section 10: Appendix C
Display Run Codes
Condition
Code
DISPLAY
Condition Code Description
0C
IDLE
>
DOWN LIMIT STANDING BY AT DOWN LIMIT (NOTE: THIS MESSAGE IS DISPLAYED IF BOTH LIMITS ARE ACTIVE)
0D
IDLE
>
UP LIMIT
STANDING BY AT UP LIMIT
0E
IDLE
>
MID STOP
STANDING BY AT MID-STOP LIMIT
0F
IDLE
>
NO LIMIT
STANDING BY BETWEEN LIMITS
10
OPENING
>
OPEN BTN OPENING FROM OPEN BUTTON
11
OPENING
>
ONE BTN OPENING FROM 1 BUTTON
12
OPENING
>
RADIO OPENING FROM RADIO
13
OPENING
>
AUX OPEN OPENING FROM AUXILIARY OPEN INPUT
14
OPENING
>
OPEN KEY OPENING FROM KEYPAD OPEN KEY
20
CLOSING
>
CLOSE PB
CLOSING FROM CLOSE BUTTON
21
CLOSING
>
ONE BTN CLOSING FROM 1 BUTTON
22
CLOSING
>
RADIO CLOSING FROM RADIO
24
CLOSING
>
CLOSE KP
CLOSING FROM KEYPAD CLOSE KEY
2A
CLOSING
>
TCM CLS
CLOSING FROM TIMER CLOSE MODULE
30
HALT
>
WALL BUTTON GDO
STOPPED BECAUSE STOP OR OPEN BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
31
HALT
>
ONE BUTTON GDO
STOPPED BECAUSE 1 BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
32
HALT
>
RADIO
GDO STOPPED BECAUSE RADIO INPUT WAS ACTIVATED, STARTING A REVERSAL
33
HALT
>
AUX. OPEN GDO
STOPPED BECAUSE AUXILIARY OPEN INPUT WAS ACTIVATED, STARTING A REVERSAL
34
HALT
>
KEYPAD KEY
GDO STOPPED BECAUSE KEYPAD STOP OR OPEN KEY WAS ACTIVATED, POSSIBLY STARTING A REVERSAL
35
HALT
>
N-O SAFETY GDO
STOPPED BECAUSE N-O REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL
36
HALT
>
ODC STB
GDO STOPPED BECAUSE ODC STB WAS BLOCKED, STARTING A REVERSAL
37
HALT
>
N-C SAFETY GDO
STOPPED BECAUSE N-C REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL
38
HALT
>
MON. EDGE
GDO STOPPED BECAUSE MONITORED EDGE SENSOR INPUT WAS ACTIVATED, STARTING A REVERSAL
39
HALT
>
DOOR FORCE GDO
STOPPED BECAUSE THE FORCE REQUIRED TO OPERATE THE DOOR WAS TOO HIGH, POSSIBLY STARTING A REVERSAL
3A
HALT
>
LOSS OF C/C
GDO STOPPED BECAUSE CONSTANT CONTACT ON THE CONTROL WAS REMOVED BEFORE REACHING A LIMIT, POSSIBLY STARTING A REVERSAL
3B
HALT
>
SHUTDOWN
GDO STOPPED BECAUSE THE GDO DETECTED A FAULT SUCH AS AN OPEN INTERLOCK, OVERHEATED MOTOR, ETC.
3C
HALT
>
DOWN LIMIT GDO
STOPPED BECAUSE IT REACHED THE DOWN LIMIT
3D
HALT
>
UP LIMIT
GDO STOPPED BECAUSE IT REACHED THE UP LIMIT
3E
HALT
>
MID STOP
GDO STOPPED BECAUSE IT REACHED THE MID-STOP LIMIT
3F
HALT
>
MODULE FAIL GDO
STOPPED BECAUSE AN EXPANSION MODULE WAS NOT WORKING PROPERLY