Section 10: Appendix B
Screw Terminal Assignments
FUNCTION
CONNECTION TYPE
11-POSITION
TERMINAL BLOCK
INSIDE ELECTRIC BOX
OPEN
Causes door to open if not at Up Limit.
Causes a closing door to reverse.
Normally-Open Dry Contact to GND.
CLOSE
Causes door to close if not at Down Limit.
Normally-Open Dry Contact to GND.
STOP
Causes a moving door to stop.
Prevents the operator from running.
Normally-Closed Dry Contact to GND.
GND
Common ground connection for Open, Close, Stop &
1-Btn Inputs.
1-BTN
Causes door to open if not at Up Limit or Mid-Stop Limit.
Causes door to close if at Up Limit or Mid-Stop Limit.
Causes door to stop if opening.
Causes a closing door to reverse.
Normally-Open Dry Contact to GND.
ODC STB
Reverses a closing door if photocell beam is blocked.
NOTE: STB's must be enabled in Calibration Mode.
Connect only ODC Series II Safe-T-Beams® to these inputs.
Connect to either terminal (not polarity sensitive).
ODC STB
Reverses a closing door if photocell beam is blocked.
NOTE: STB's must be enabled in Calibration Mode.
Connect only ODC Series II Safe-T-Beams® to these inputs.
Connect to either terminal (not polarity sensitive).
N-O SAFETY
Causes a closing door to reverse.
NOTE: Will not open a stopped door.
Normally-Open 2-Wire Non-Monitored Edge Sensor
Connect to either terminal (not polarity sensitive)
N-O SAFETY
Causes a closing door to reverse.
NOTE: Will not open a stopped door.
Normally-Open 2-Wire Non-Monitored Edge Sensor
Connect to either terminal (not polarity sensitive)
EXT INTLK
Causes a moving door to stop.
Prevents the operator from running when contact is open.
Operates even if microcontroller is non-functional.
Normally-Closed dry contacts.
(board will energize these contacts at n24VDC).
EXT INTLK
Causes a moving door to stop.
Prevents the operator from running when contact is open.
Operates even if microcontroller is non-functional.
Normally-Closed dry contacts.
(board will energize these contacts at n24VDC).
2-POSITION TERMINAL
L1 / L1
Power to RMX™ operator.
120VAC: Connect to Line (Hot) / 240VAC: Connect to Line 1.
BLOCK
INSIDE ELECTRIC BOX
N / L2
Power to RMX™ operator.
120VAC: Connect to Neutral / 240VAC: Connect to Line 2.
3-POSITION TERMINAL
STRIP
ON OUTSIDE OF
ELECTRIC BOX
PWR
Provides power for radio & other accessories.
+20 to +40VDC, fused at 315mA (F1).
Connect to radio or other accessory's power input.
RAD
GND
Causes door to open if not at Up Limit or Mid-Stop Limit.
Causes door to close if at Up Limit or Mid-Stop Limit.
Causes a closing door to reverse.
Common ground connection for PWR and RAD terminals.
Connect to radio or other accessory's ground input.
EXPANSION PORT Connects accessory modules to RMX™ operator.
Accessory Module Ribbon Cable.
PLUG CONNECTIONS
INSIDE ELECTRIC BOX
TRANSFORMER
Connects main transformer to control board.
Transformer Plug.
TRANSFORMER
Connects optional second transformer to control board.
Transformer Plug.
BRAKE
Connects brake solenoid to control board.
Brake Solenoid Plug.
MOTOR
Connects motor & capacitor to control board.
Motor Plug.
HOIST INTLK
Causes a moving door to stop.
Prevents the operator from running.
Operates even if microcontroller is non-functional.
Hoist Interlock Plug or Jumper.
INPUT
(Radio Input Control)
07/30/09