FOR ASSISTANCE CALL 1-800-275-618
7
6.6
The RMX™ Operator will automatically set its maximum run timers
(MRT) when the unit is run from limit to limit in the run mode. The Max
Run Timer is a feature that prevents the unit from running continuously
in the event of a slipping clutch, etc.
NOTE
: The MRT’s are set to the time required to run from one limit to
the other, plus 5 seconds (nominal). When the MRT is exceeded, the
operator stops and may reverse (only on a close attempt with trolley
unit). The operator will not respond to any command until it is reset by
pressing one of the calibration keys or by cycling power to the unit.
Resetting the Max Run Timers
The Maximum Run timers can be reset to their default values using this
procedure:
1) Press CAL/RUN to enter calibration mode.
2) Press Scroll (DN) until display reads “MAX RUN TMR
>
SET.”
3) Press SET/CLEAR until display reads “MAX RUN TMR
>
CLEAR.”
FIG. 1
0
.
4) Press CAL/RUN to return to run mode.
NOTE
: The Max Run Timers must be reset each and every time the
travel limits are adjusted.
CAUTION:
The Mid-Stop feature must be turned off to properly set the
maximum run timers.
Max Run Timer
MAX RUN TMR CLR
Figure 1
0