FOR ASSISTANCE CALL 1-800-275-6187
6.1
RMX™ Operators include a full function control panel including a liquid
crystal display (LCD), calibration keys and Open, Close and Stop keys for
on board operator control. See
Fig. 1
. The open, close and stop keys
function as a 3-button wall control. The Display will show current
operator conditions and calibration information. Due to limited
character space, some displays will be abbreviated.
See Appendix C (pgs. 10.11-10.13) for full display descriptions.
RMX™ Operators include a non-volatile memory. The unit will
remember all calibration settings plus error code and run code logs, if
power is removed from unit.
NOTE
: During Setup, refer to Caution Label for limited use (pictured on
page 5.4).
DANGER
After power is supplied to the operator,
Do Not
make contact
with components inside the control panel except for the
Keypad Keys.
Fig. 1
.
Control Operating Modes
RMX™ Operator control boards operate in two modes: Run Mode and
Calibration Mode. The control board should normally operate in the
Run Mode. The operator is calibrated in Calibration Mode.
With the operator standing idle
:
PRESS CAL/RUN TO TOGGLE BETWEEN OPERATING MODES.
• The first display in calibration mode is "open mode
>
***”
(*** = current operating mode).
• The display in run mode will be one of the condition codes listed
in Appendix C.
NOTE
: The CAL/RUN key will not toggle between operator modes while
the operator is running.
Section 6: Operator Setup Procedure
Control Panel
LCD DISPLAY
Figure 1
Calibration &
Run Mode
Toggle Key.
Display
Backlighting
Toggle Key.
Scroll Keys, used in
Calibration Mode.
Set/Clear Key,
used to reset
and adjust
calibration
settings.
Operation Keys,
operates unit
like a 3-button
wall station.
07/30/09