FOR ASSISTANCE CALL 1-800-275-6187
6.7
The RMX™ Operator includes a programmable Mid-Stop. This feature
allows the operator to stop at a user selectable point when opening. It is
used when operating very tall doors that only open to their full height
occasionally. The Mid-Stop does not effect the operator when closing.
1) To operate door to full open position from mid-stop, press open
button again.
NOTE
: Setting of the MID-STOP should only be performed AFTER Travel
Limit and Max Run Timer settings have been made.
To set the Mid-Stop
:
1) Press CAL/RUN to enter calibration mode.
2) Press the CLOSE key to close the door to the down limit.
3) Press SCROLL (DN) until the display reads “MID-STOP
>
CLEAR.”
Fig. 1
1
.
NOTE
: If the display reads MID-STOP
>
SET at this point, first clear the
MID-STOP as described below then repeat steps 1-3 and continue.
4) Press the OPEN key to open the door and release the key
when the door is at the desired Mid-Stop height.
5) Press the SET/CLEAR until the display reads “MID-STOP
>
SET.”
6) Press CAL/RUN to return to run mode.
To clear the Mid-Stop
:
1) Press CAL/RUN to enter calibration mode.
2) Press SCROLL (DN) until the display reads MID-STOP
>
SET.
3) Press SET/CLEAR until the display reads MID-STOP
>
CLR
4) Press CAL/RUN to return to run mode.
Setting the Mid-Stop
MID-STOP CLR
Figure 1
1
07/30/09