Smart Type
B-526-10N-E
13
5.2 Smart Type ULTRA register
5.2.1 About "MODE" Switch
Removing the selector magnet inserted at the
bottom of the register, apply it to the label "MODE"
on the LCD counter face and the display will scroll
forward through the available readings as shown.
CAUTION
Do not fail to install the selector
magnet in its holder after use
lest you will not lose it. It uses an
intensive magnet; never hold it close
to floppy disks or other magnetic
storage media.
SELECTOR MAGNET
SELECTOR MAGNET
“MODE”
5.2.2 About "RESET" Switch
The display can show four different kinds of flow
information - total flow, instantaneous actual
flowrate, percent instantaneous flowrate, and
8-division percent bar graph.
It also shows the following error messages:
Full scale exceeded:
ErrorFS
Upper-limit flowrate exceeded:
ErrorOF
NOTE:
Multiple errors will be indicated in priority
order below:
ErrorOF
>
ErrorFS
5.2.3 Display Selection
Two ways are available to select displays - with a
display select switch inside the register, or through
communications with the Smart Communication
Unit Model EL2310 (or HHC: Model EK10).
If your option is through communications, follow the
instructions outlined in the Smart Communication
Unit EL2310 (or HHC: EK10) instruction manual.
NOTE:
Show "Transmitter Info." Window at
"Configure" menu on the PC screen.
Selection with display select switch requires access
to the display select switch SW1 by opening the
register cover facing its internal assembly and
pressing this switch (see page 35). The display
scrolls forward through available information each
time you press this switch as shown in Fig. 5.1.
TOTALIZED FLOW
EXAMPLE OF READINGS
INSTANTANEOUS
ACTUAL FLOWRATE
% INSTANTANEOUS
FLOWRATE
8-DIVISION
BAR GRAPH
MODE SYMBOL
Fig. 5.1