9. CHANGE OF SETTING VALUE
9.1 Parameter setting
The parameters can be set on [PARAMETER] screen.
However, if a password is set, the screen will be expanded after the password is certified.
The batch setting volumes C1 to C9 can be set only in the parameter setting menu.
The batch setting volume CF (free) can be set from batch processing screen at the usual operation.
In case of 0, you can
’
t start filling operation.
NOTE:
No.
Item
Range
Standard
value
Remark
C1 Channel 1
0 to 999999 count
0
Sets the batch setting volume of channel 1 [C1].
C2 Channel 2
0 to 999999 count
0
Sets the batch setting volume of channel 2 [C2].
C3 Channel 3
0 to 999999 count
0
Sets the batch setting volume of channel 3 [C3].
C4 Channel 4
0 to 999999 count
0
Sets the batch setting volume of channel 4 [C4].
C5 Channel 5
0 to 999999 count
0
Sets the batch setting volume of channel 5 [C5].
C6 Channel 6
0 to 999999 count
0
Sets the batch setting volume of channel 6 [C6].
C7 Channel 7
0 to 999999 count
0
Sets the batch setting volume of channel 7 [C7].
C8 Channel 8
0 to 999999 count
0
Sets the batch setting volume of channel 8 [C8].
C9 Channel 9
0 to 999999 count
0
Sets the batch setting volume of channel 9 [C9].
CF Cannel free
0 to 999999 count
0
Sets the batch setting volume of channel free [CF].
02 Scaler value
0 to 999999 count
1
Sets the coefficient value to be used for obtaining the integrated flow rate.
03 Initial setting value 0 to 9999 count
80
Sets the timing for opening MV (large valve).
If it is set to initial setting value [80] and the batch setting volume is set to
[1000], the MV opens when the integrated value reaches 80.
04 Terminal setting
value
0 to 9999 count
80
Sets the timing for closing MV (large valve).
If it is set to initial setting value [80] and the batch setting volume is set to
[1000], the MV closes when the integrated value reaches 920.
05 Overrun forecast
value
0 to 99 count
2
Sets the timing for closing SV (small valve).
If the overrun forecast value reaches is set to [2] and the batch setting volume is set
to [1000], the SV closes when the integrated value reaches 998.
06 Overrun volume
0 to 99 count
2
Sets the timing for generating overrun alarm.
If the batch setting volume is set to [1000] and the overrun volume is set to [2],
<E2> alarm is generated when the integrated value reaches 1002 within the
completion monitoring time.
07 Leak failure
setting value
0 to 99 count
10
Sets the time for generating leak alarm.
If the leak failure setting volume is set to [10], <E3> alarm is generated when 10
count up between completion and start of batch operation.
08 Non-arrival pulse
interval time
0 to 999sec
5
Sets the timing for generating pulse non-arrival alarm. It is also possible to
disable the monitoring of non-arrival of pulse by setting it to 0 second. If the
non-arrival pulse interval time is set to [5], <E1> alarm is generated when the
non-arrival time of pulse reaches 5 seconds.
09
Completion
monitoring
setting value
0 to 99sec
5
The completion monitoring time is set for monitoring the overrun alarm after
the batch volume integrated value reaches the setting value.
The completion monitoring time is counted after the batch volume integrated
value becomes same as batch setting volume. The batch becomes END after
the time set by parameter is over.
0A Accumulation counter
0 to 999999
0
Sets the accumulated total value up to 6 digits. Up to 9 digits can be counted on the display.
0B Pump output
delay timer
0 to 9999sec
30
Sets the time for continuing the pump output after SV is closed.
If the pump output delay timer is set to [30], the pump output is turned OFF in
30 seconds after the import is completed.
0C Buzzer ON time
setting
0 to 999sec
0
Sets the time in which alarm buzzer is turned ON.
0: continued 1 to 999: sounds within the setting time (1 to 999 seconds)
0D
Batch setting
volume upper limit
setting value
0 to 999999 count
999999
Disables the setting of batch volume exceeding the batch setting volume
upper limit setting value by parameter setting.
When you set the parameter C1 to CF, a value exceeding the upper limit
value cannot be set. If a value more than upper limit value is set for C1 to CF
preliminarily, the operation cannot be started.
0E Reset start
function
0: without, 1: with
0
Enables or disables the reset start function.
[0] Disabled, [1] Enabled
0F Measure unit
0:
×
1000
1:
×
100 2:
×
10 3:
×
1
4:
×
0.1 5:
×
0.01
6:
×
0.001
3
Sets the unit coefficient.
[0] 1000, [1] 100, [2] 10, [3] 1, [4] 1/10, [5] 1/100, [6] 1/1000
11 Accumulated
display time
0 to 9sec
0
Sets the time in which accumulated total value is displayed when TOTAL button is input.
0: Accumulated total value is displayed while TOTAL button is input 1 to 9:
Automatically reset to preset value display after the setting time is over
12 Operation switch
selection
0: Front (front surface
setting mode
1: Remote (external setting
mode)
0
Selects the setting method of switch operation.
[0] Front surface setting mode
[1] External setting mode
13 Pulse output width 0: 150
μ
sec 1: 1msec 2: 50msec
1
Sets the pulse width of output pulse.
14 Input division
0: 1/1
1: 1/10 2: 1/100
0
Sets the input division by software.
15 Output division
0: 1/1 1: 1/10 2: 1/100
3: 1/1syn
0
Sets the division of output pulse.
16 Integration unit
0: --(blank) 1: mL
2: L
3: kL
4: m
3
5: g
6: kg
7: t
8: USG
9: barrel
0
Sets the integration unit of display.
17 Sleep mode
0: OFF 1: ON
1
Enables or disables the sleep mode for protecting backlight.
0: always displayed while the power is distributed
1: mode shifts to sleep mode if nothing is operated for 1 minute or
more during other than batch operation
20 Language
0: Japanese 1: English
1
Sets the display language.
※
This item is not displayed on PARAMETER screen. The language is
switched from SYSTEM screen.
21 Password
111111
Sets the password.
※
This item is not displayed on PARAMETER screen. The password is
switched from SYSTEM screen.
H1 System Ver.
You can check the system version.
The system version may be changed without notice depending on the
product.
※
This item is not displayed on PARAMETER screen. You can check
the version from SYSTEM screen.