E-216-5N-E
10
5.7 Example of Hookup
Fig. 5.2 Exampl of Wiring Connections (Terminal block)
If the external operation input STOP is not used,
STOP(19) to COM.(20) should be always short-
circuited. If the interlock is not used, I.LOCK(25)
to COM.(26) should be always short-circuited.
Terminal connection diagram
(silk on left side of this device)
Output to remote totalizer
counter, etc.
Open collector
200msec.min.
200msec.min.
200msec.min.
200msec.
min.
200msec.
min.
Power: 85 to 264VAC
50/60Hz
Operation
Stopped
STOP (contact b)
RESET (contact a)
START (contact a)
Alarm output LED lamp etc.
can be driven
Pump can be operated /
stopped for batch
processing
CORIOLIS FLOWMETERS
OVAL FLOWMETER
ALTImass Type S
ALTImass Type U
ULTRA
MK
Flow signal input.
(std.)
Pump output
SV
MV
COM
SV
MV
COM
Valve
R C
R C
Surge suppressor
Air
supply ?
Combination filter/reducing valve
Two-stage shutoff valve
3-way Directional valve
Valve operation output
Remote Control Input
Short-circuited when
an interlock is not used
Function such as LED
light up when batching
completes is enabled
Output to External Totalizer
OVAL flowmeters,
Coriolis flowmeters,
etc.
CAUTION:
* The flowmeter shown here
is an example.
It is recommended to attach the surge suppres-
sor etc. to the induction load side to protect the
contact.
CAUTION: