E-126-3-E
-
Place where is not exposed to rain or water
-
Place where vibration or shock is rarely generated
-
Room-temperature and room-humidity place
-
Storage / shipment environment condition
Temperature: 20
±
15
℃
Relative humidity: 65
±
20%
Atmosphere pressure: 500 to 1060hPa
This instrument has IP67 class performance,
however, when it is used at a place exposed to direct
sunlight or change of weather constantly, enclose it
with shielding object such as roof to protect the
instrument during use.
Do not install the product at a place where thumping
vibration is generated, and install it on stable
structure without effects of vibration.
Fig. 1.4 Precautions on installation location
1.2 Precautions on transportation
(1) To prevent the instrument from being damaged by an accident during transportation, convey this instrument
to the installation location in the original packing style shipped from our company whenever possible.
(2) Take care not to apply strong shock to the instrument or get it wet with rain during the conveyance.
1.3 Precautions on storage
After receiving this instrument, an unexpected accident may occur if the elapsed time before installation is long.
If the long-term storage is expected, pay attention to the following items.
(1) Store this instrument in the original packing style shipped from our company whenever possible.
(2) The storage place should meet the conditions shown below.
1.4 Precautions on use conditions
To keep accuracy of totalizer and long-term durability, it is necessary to use the product under the designated
conditions of ambient temperature and rated power (signal) etc. These use conditions are shown in the section
"3. Specifications / performance". Please be sure to check it before the operation.
If you want to change the use conditions, please contact us.
1.5 Precautions on installation location
The ambient operating temperature of totalizer is -20°C to +55°C (in case of non-explosionproof type, -40°C to
+70°C). If the totalizer may be exposed to high temperature due to direct sunlight and reflected heat etc., set up
sunshade etc. and use the product within the use temperature range. Do not put an object within 10cm from front
surface of product (glossy object causes wrong reaction of optical switches and may affect the life duration of
battery).
Summary of Contents for EL0137
Page 37: ...E 126 3 E 37...