Last Update: 2011-June INSTRUCTION MANUAL FOR THERMOSYPHONIC SYSTEMS
9/35
©TANSUG MAKİNA LTD. 2008
2.4
Technical Specifications of Horizontal Boilers
HIGHLIGHTS OF OURASET P SERIES
*
Aesthetic Uv resistant ABS Plastic Caps designed for easy handling
*
Minimum heat loss due to dense polyurethane insulation
*
Enatech porcelain enamel coating to ensure hygienic water
*
Electrical heater inlet and cap available
*
Extra-durable external case, color coated galvanized, suitable to locate outdoors
*
Mg anode, enamel protection and inspection/cleaning hole for extended tank life
Code
P 120
P 150
P 190
P 300
Net Capacity
120 lt.
150 lt.
190 lt.
300 lt.
External Casing
*Case: Colorcoated® galvanized steel,
coated with transparent folio for protection during
transport
* Caps: UV-Proof ABS plastic
Diameter ( ø )
(mm)
500 mm
600 mm
600 mm
600 mm
Length (L) (mm)
1200 mm
1000 mm
1500 mm
1800 mm.
Tank Body
Material (mm)
Low carbon steel
3 mm
Low carbon steel
3 mm
Low carbon steel
3 mm
Low carbon steel
3 mm
Jacket material
(mm)
Low carbon steel
Low carbon steel
Low carbon steel
Low carbon steel
1,5 mm
1,5 mm
1,5 mm
1,5 mm
Tank Internal
Protection
enatech porcelain
Enamel coating
150-400 micrones
enatech porcelain
Enamel coating 150-
400 micrones
enatech porcelain
Enamel coating 150-
400 micrones
enatech porcelain
Enamel coating 150-
400 micrones
Cathodic
Protection
Magnesium anode rod 50 cm
Test Pressure
(bar)
Body: 9 bar
Jacket: 4 bar
Insulation (mm)
ASSET - Polyurethane Injection (42 kg/m³)
40 -50 mm
40 -50 mm
40 -50 mm
40 -50 mm
Water Inlet –
Outlet
¾”
¾”
¾”
¾”