There are two alternative ways to set the Ouflex M device IP address 
and network settings: 

1.  IP address is retrieved via DHCP function. This requires that 

DHCP service is in use in the network and network cables have 

been connected. 

2.  IP address is set manually.

1.  Request correct network settings (IP address, Gateway address, 

Subnet mask, Nameserver address) from the network administra-

tor.

2.  Go to “System settings” -> “Network settings” -> “DHCP” and 

press 

 

 

3.  Select ”Off” and press 

 

 

 

 to accept selection. 

4.  Enter all network settings (IP address, Gateway address, Subnet 

mask, Nameserver address) provided by the network administra-

tor.

5.   Select ”Update network settings” . 

System settings > Network settings

The Ouman Access service offers a secured connection to automati-
on equipment using the in-house internet connection. Buy equipped 
with a data interface SIM card 

Network settings

1.  Go to DHCP and press 

 

 

.

2.  Select ”On” and press 

 

 

 

 to accept selection.

3.  Select ”Update network settings” and press 

 

 

 

 to accept selec-

tion.

4.  Wait approximately one minute.
5.  The network settings are now assigned to Ouflex M by DHCP 

server (new settings should appear automatically in the user in-

terface) 

Otherwise check the network connections and ensure that 

DHCP-server is available in the network.

Setting the IP address via DHCP function:

Setting the IP address manually:

1.3 Network settings

If you want to connect the Ouflex M unit to an Ethernet network, 

you will need an Oulink Ethernet adapter (additional equipment).   

Oulink Eth is connected to COM3 port (RJ-45) located in the side 

of the controller. The maximum length of the RJ45 ethernet cable 

between Ouflex M and Oulink is 10m and all 4 pairs must be con-

nected.

SMS PIN

Approve: Press and hold OK 
Cancel: Press and hold ESC

Network settings

Network settings

System settings

RJ-45 сonnector to the Oulink

8

7

6

5

D

C

B

A

B

C

D

E

F

1

2

3

4

5

6

7

8

F

E

A

Date

Pages

Author

Designer

Scale

Document type

Document description

Item

Document code and revision

1/1

Modifier

Page size

1:1

A4

XL740-A-01

Printing color: RAL 9005 Jet Black

Drawing

OUFLEXMINI PRINTED COVER

09.06.2015

MM

--

--

XL740

9 10

11 12

13 14

15 16

17 18

19 20

C NO

C NO

C NO

C NO

C NO

C NO

1 2

3 4 5

6 7 8

24V ~/+ 

B2 A2

B1 A1

21

22 32 42

25

62 72 82 29 03 13 23 33 43 53 63

37

83 93 04

41

24 34 44

45

64 74 84 49 05 15 25 53 45 55 65

57

85 95 06

Y1

PWM

Y3

2Y

M5

4Y

M4

M3

M2

M1

M14

51

M

M12

31

M

M10

M11

M9

M8

M7

M6

Print1)

Print2)

Print3)

Time                                   17:01>
Date                        17.01.2017 >
Day light saving            In use >
Language                    English >
SMS settings                            >

Network settings                    > 

Display settings                        >
Type info                                    >
Lock code              Not in use  > 
     Backup                                   >

DHCP                                    Off >

Gateway adress           0.0.0.0 >
Subnet mask                   0.0.0.0 >
IP address                       0.0.0.0 >
Nameserver address    0.0.0.0 >
Update nework settings         >
- - - - - - - - - - - - - - - - - - -   - - -
FTP                                          On >
Modbus TCP/IP gw                     >
Modbus RTU slave                      >
Modbus RTU master 1                >
SNMP                                             >
Access                                                                      On    >                                                   
Access IP                         0.0.0.0 >
- - - - - - - - - - - - - - - - - - - - - - - -
OULINK                                             
Serial number
Device state            Uninitialized>
WEB user interface                 On>
OPC UA                                              Off >
OPC UA Portti                            48010 >
<- - 

DHCP                                    Off >

Gateway adress           0.0.0.0 >
Subnet mask                   0.0.0.0 >
IP address                       0.0.0.0 >
Nameserver address    0.0.0.0 >
Update nework settings         >
- - - - - - - - - - - - - - - - - - -   - - -
Modbus TCP/IP gw                     >
Modbus RTU slave                      >
Modbus RTU master 1                >
SNMP                                             >
Access                                                                      On    >                                                   
Access IP                         0.0.0.0 >
- - - - - - - - - - - - - - - - - - - - - - - -
OULINK                                             
Serial number
Device state            Uninitialized>
WEB user interface                 On>
OPC UA                                              Off >
OPC UA Portti                            48010 >
<- - 

Summary of Contents for Ouflex M

Page 1: ...pplication to the controller by using SD card M OUFLEX USER MANUAL Ouflex M is a DIN rail attachable monitoring controlling and regulating device Ouflex M can be as a master device and slave device in...

Page 2: ...he beeper stops The beeper can be turned off with active alarms present by pressing the ESC button When you do so the window with details of the most recent alarm on the screen will close To view acti...

Page 3: ...isplay settings 9 1 5 Type information 9 1 6 Lock code 9 1 7 Restore settings and updates 10 2 Alarms 11 3 Point info 13 3 1 Wiring info 13 3 2 Bus points 13 3 3 Time programs 13 4 Settings 15 5 Measu...

Page 4: ...vings and leap years into account automatically The clock has a backup for power outages lasting at least three days 1 Set hours and press to accept 2 Set minutes and press to accept 3 To exit without...

Page 5: ...S e g TC01 IN PUTS Signal strength Signal strength is expressed with the following descriptions Excellent Good Moderate Low Very low and Initialization failed If signal strength indicates No network t...

Page 6: ...rt RJ 45 located in the side of the controller The maximum length of the RJ45 ethernet cable between Ouflex M and Oulink is 10m and all 4 pairs must be con nected SMS PIN Approve Press and hold OK Can...

Page 7: ...have the same bus address All devices in the bus should be set to the same setting value of the baud rate data bits stopbitteihin and parity System settings Network settings Modbus TCP IP If the Ouma...

Page 8: ...billing information to the Ouman system and activates the service based on the serial number of the Oulink After that you have to activate the ACCESS service from the device OUMAN ACCESS device can be...

Page 9: ...Network settings Display settings Type info Lock code Not in use Lock code In use Not in use Give lock code 0 0 0 0 Approve Press and hold OK Cancel Press and hold ESC When lock code is taken in use...

Page 10: ...microSD memory card from Ouflex M 2 Wait until error message Memory card error is shown in the display 3 Insert new microSD memory card which includes new software to Ouflex M 4 Ouflex M asks if you...

Page 11: ...t alarm history Routing schedule Alarm receivers Alarm sound On 2 Active alarms 07 12 2016 12 24 52 Risk 08 01 2017 01 12 40 Sen 2 Risk of freeze PR 1 GROUP 1 Pump has stopped 0 Received 06 11 2017 02...

Page 12: ...Adding a new switch time 1 Press at the Add new row 2 Press Set the switch time for alarm routing set hours and mi nutes separately and press 3 Press OK and then turn the control knob to set the alarm...

Page 13: ...rcuit board temperature The outputs have a Sounder selection which allows you to set the alarm sound off if you want In the bus points menu you can see those devices which are con nected to the bus By...

Page 14: ...ng mode Weekly schedule 0 3 6 9 12 15 18 21 24 MO TU WE Exception schedule Point info Time programs Exception schedule You can easily make changes that differ from normal routine use by using the exce...

Page 15: ...s You can hide show these settings by pressing OK for a few se conds When visible these settings are shown slightly indented Settings that require maintenance code There is a symbol in front of these...

Page 16: ...prove Press and hold OK Cancel Press and hold ESC A t Name of room 1 6 Naming Huoneiden valinta Huoneen 1 nimi Huone 1 Huoneen 2 nimi Huone 2 r m Automatic control is the mode that is normally used If...

Page 17: ...write the key word using capital or small letters Write only one key word per message Store the key words into your phone s memory If a GSM modem is connected to the Ouflex M you can communicate with...

Page 18: ...dem Do not pull the slot out of the modem without pres sing the SIM card release button first Insert SIM card into the slot and make sure it settles properly Push the slot back to its place Set the SI...

Page 19: ...M3 26 GND 27 M4 28 GND 29 M5 30 GND 41 M6 42 GND 43 M7 44 GND 45 M8 46 GND 47 M9 48 GND 49 M10 50 GND 3 Detachable strip connectors passive sensors active sensors and digital inputs 51 M11 52 GND 53 M...

Page 20: ...M11 M15 5 pcs active sensors 0 10 V M11 M15 from HW ver 1 0 Analog outputs Y1 Y4 4 pcs Output voltage range 0 10 V Output current max 10 mA output PWM output 1 piece that works in parallel with the Y1...

Reviews: