Appendix B: Installing the SE 200 in an observation
well
The SE 200 can also be installed in 4"; 4,5"; 5" or 6" observation wells using the
observation well installation set (accessories).
OTT or HT top caps are to be used to seal the pipes (others on request). You can
also use a contact gauge with the installed observation well installation set. In the
process, the measuring tape is then passed in front of the holding bracket.
Proceed as follows to install:
䡵
Select the right fastening ring to fit the existing observation well.
䡵
Assemble the observation well installation set and the SE 200 as shown in
Figure 10; install the fastening ring only as shown! Hex head cap screws are
provided for the guide rollers; tighten these screws only slightly (self-locking).
䡵
Fix the transducer cable to the holding bracket using a cable tie.
Then turn to Chapter 5.