10 Technical Data
M
easuring range
SDI-12
±30 m; ±98.424 ft
4 … 20 mA
0 … 1 m; 0 … 10 m; 0 … 30 m
0 … 3 ft; 0 … 30 ft; 0 … 90 ft
Resolution
SDI-12
0.001 m; 1 cm; 0.001 ft
4 … 20 mA
0.1 % of the measuring range
Precision
1)
SDI-12
± 0.003 % of the measuring range ± 1 digit
4 … 20 mA
0.1 % of the measuring range
Units
SDI-12
m; cm; ft
Interfaces
SDI-12 or SDI-12/4 … 20 mA
Supply voltage
9 to 30 V DC
Current drawn
SDI-12 Sleep mode
< 400 µA
SDI-12 Active mode
< 2.0 mA
Dimensions L x W x H
82 mm x 82 mm x 34 mm
Weight
0.250 kg
Casing material
Fiberglass reinforced plastic
Type of protection
IP 54
Temperature range
Operational
–20 … +70 °C
Storage
-40 … +85 °C
Relative humidity
10 … 95 % (non-condensing)
Float pulley circumference
200.0 mm
Standard float cable
1 mm Ø
other diameters are scalable; e.g. 0.6 mm
float cable -Ø, adjust float pulley circum-
ference to 198.7 mm
Connecting cable
Length
10 m, 15 m or 30 m
Wire assignment
– green
SDI-12 GND
– brown
+V
CC
(typ. 12 V DC) or V
+
(4 … 20 mA)
– white
GND or V
–
(4 … 20 mA)
– yellow
SDI-12 data
E
M
C limits
– Resistance to
complies with EN 61000-4-2 degree of
electrostatic discharge (ESD)
severity 2 (4 kV contact discharge)
– Resistance to
complies with EN 61000-4-3 degree of
electromagnetic fields
severity 3 (10 V/m)
– Resistance to transient
complies with EN 61000-4-4 special
fields (burst)
degree of severity (4 kV)
– Resistance to surge
complies with EN 61000-4-5 degree of
(1 kV)
severity 2
– Line-borne and radiated
complies with EN 55022 Class B
interference
1)
Base precision SE 200 (without float/float cable/counterweight)