4.1 Installing the SE 200 as a stand-alone device
Please refer to Figures 2 + 3 and proceed as follows:
Fastening the SE 200
䡵
Attach SE 200 to connection angle B (
M
6 x 16 + washers); attach connection
angle B to a flat base with double-sided adhesive strips (if necessary: use
screws in addition). Alternatively: Attach the SE 200 directly to a suitable
vertical mounting wall using
M
6 x 25 screws and washers.
Installing the float, float cable and counterweight
䡵
Determine the distance from minimum (lowest) water level to the upper edge of
the SE 200; add approxiamtely 50 cm to this value = length of the float cable;
cut float cable to length.
䡵
Form loops at either end of the float cable; slip the sleeves over the loops and
pinch with a flat nose pliers; suspend float and counterweight inside the loops.
䡵
Place the float cable over the float pulley; allow the float unit to stabilise.
Tip
:
Use a safety device (such as a hook or a screw) to prevent possible loss of the
float and counterweight while installing them!
Now turn to Chapter 5.
4.2 Installing the SE 200 as an attachment
see Appendix A
4.3 Installing the SE 200 in an observation well
see Appendix B
Sa
f
ety device
Co
nn
ecti
n
g
a
n
gle B
M 6 x 16 +
washer
SE 200
Sleeve
Float cable
Co
nn
ecti
n
g li
n
e
Adhesive
strips
Fig. 3: Installing the SE 200
as a stand-alone device.
Install connecting angle B
so that it points forward!