SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
31217156
6-11
General Maintenance Tips
NOTE:
Be sure to lubricate like items on each side of machine.
NOTE:
Recommended lubricating intervals are based on machine oper
-
ations under normal conditions. For machines used in multi-shift
operations and/or exposed to hostile environments or condi
-
tions, lubrication frequencies must be increased accordingly.
Operate hydraulic functions through one complete cycle before
checking hydraulic oil level in tank. Oil should be visible in ADD
sight window on hydraulic tank. If oil is not visible, add oil until
oil is visible in both ADD and FULL sight windows on tank. Do
not overfill tank.
Any time the pump coupling is removed, coat splines of coupling
with Texaco Code 1912 grease prior to assembly.
1.
Safety Prop Actuator Rod
2.
Notch Flats on Rod
3.
Rod Keeper Plate