SECTION 3 - MACHINE CONTROLS, INDICATORS, AND OPERATION
31217156
3-5
Indicators
DO NOT OPERATE FROM GROUND CONTROL STATION WITH PERSONNEL IN THE PLAT
-
FORM EXCEPT IN AN EMERGENCY.
1. Ground/Platform/OFF Key Selector
Switch
-
A three position, key-operated power
select switch supplies operating power
to the platform or ground controls, as
selected. When positioned to platform,
the switch provides power to the emer
-
gency stop switch at the platform con
-
trols. When positioned to ground, the
switch provides power to the ground
control. The ground control emergency stop switch provides
power to the key switch. With the power select switch in the
center off position, power is shut off to both platform and
ground controls and the key can be removed to disable the
machine.
2. Circuit Breaker -
The circuit breaker will
open when there is a short or overload on
the machine.
3. Emergency Stop Switch -
A two-position,
red, mushroom-shaped emergency stop
switch, when positioned to ON with the
power selector switch positioned to
ground, furnishes operating power to the
ground control station. In addition, the
switch can be used to turn off power to the
function controls in the event of an emergency. Power is
turned on by pulling the switch out (on), and is turned off by
pushing the switch in (off).
4. Head and Tail Lights - ON/OFF Switch (If
Equipped) -
This toggle switch turns the
head and tail lights on and off.