SECTION 3 - CHASSIS & SCISSOR ARMS
3-34
31215074
Table 3-3. Fault Codes (Green Power)
Flash Code
Cause
Solution
1
Connection Issue
1) Check battery connection is correct.
2) Check charger connection is correct.
3) Check each battery is good.
2
Abnormal AC Power Input (Voltage)
1) Check AC input cord is connected between charger and AC outlet.
2) Make sure AC plug is tightly secured into AC outlet.
3
Charger High Temperature Protection
1) Charger shuts down and goes into protection mode due to
charger/environmental temperature is too high for charger to
function properly. Please place the charger into an area with ambi
-
ent air flow or to a cooler place.
2) Disconnect the charger and wait for 15-20 mins before reco nect
-
ing for charging.
4
Battery High Temperature Protection
1) Charger will reduce or even stop charging when the battery tem
-
perature exceeds 50° C. This is to avoid battery overheating.
2) Disconnect the charger and wait for 15-20 mins before recon
-
necting for charging.
5
Output Current is too high
Return to factory for repair.
6
Battery Voltage is too high(>30.5 V)
Check and assure that the correct output battery voltage is
connected.
7
Battery Voltage is too low(<18 V)
Check and assure that the correct output battery voltage is
connected.
Go
to
Discount-Equipment.com
to
order
your
parts