27
Caution:
Other maintenance operations, (not described herein) including replacement of lamps with lamps of the same
model, have to be commissioned to authorised centres of assistance or qualified personnel.
13 - Emergency situations
Caution:
if the cabinet should stop or fail to start
-
Make sure there is not a situation of electrical black-out
-
Make sure the switch on the control panel has been pressed
If the stoppage is not due to one of these causes, call the nearest service center and empty the cabinet. Place the
products in cold rooms designed for maintenance and storage.
Caution:
if the cabinet does not chill sufficiently
-
Make sure the condenser is clean and capable of performing its heat exchange function. If not, read Par. 12.
-
Make sure the cabinet is correctly loaded and that the air vents are unobstructed. If not read Par. 8.
-
Make sure the evaporator is not covered with ice. If not read Par. 12.
-
Make sure the cabinet is not close to a draft or heat source (see Par. 4).
-
Make sure the cabinet is level and the environmental conditions listed in Par. 4 are respected.
If after checking all these things the problem persists, call the nearest service center.
Caution:
in case of a gas leak or fire, do not go near the motor compartment. Disconnect power to the cabinet. Do not
use water to extinguish flames. Use only a dry fire extinguisher.
14 - Accessories
The Vega and Gemma can, on request, be equipped with the following accessories:
-
Refrigerated storage with drawers
-
Front lighting
-
Additional lighting inside the basin
-
Knife holder
-
Stainless steel sink
-
Plexiglas change dish
-
Socket-holder kit
-
Working shelf extension
-
Cutting board
-
Wrapping board
-
Stainless steel paper holder
-
Refrigerated display area with secondary fluid (advisable for meat only)
-
Electric defrosting kit.
If you are interested in purchasing any of the above accessories, please contact your nearest dealer or the manufacturer
directly. Only qualified personnel should assemble the electric defrosting units.
15 - Service
If you require the services of an expert, and whenever you have to replace mechanical, electrical or compressors, the
user can contact the distributor where the cabinet was purchased, to order original spare parts.
16 - Dismantling and elimination of cabinet
For environmental reasons and in compliance with the regulations in your country, separate the parts of the cabinet for
disposal and/or recycling.
All the parts that make up the cabinet are made of materials that are not classifiable as urban waste except for the
metallic parts that are not classified as special waste in most countries. As regards the parts of the refrigeration circuit,
that is the refrigerating gas and lubricating oil, these should not be disposed of carelessly and can be recycled by
specialized centers.
The gas contained in foam polystyrene for thermal insulation of the cabinet is (CO
2
).
This product contains HFC, namely fluoridated gasses, a refrigerating gas with a high Global Warming Potential
(GWP) regulated by the Kyoto protocol.
Oscartielle equips its plug-in cabinets with the following types of refrigerating gasses:
R 290; GWP
(100)
= 3
R 134A; GWP
(100)
= 1300
R 452A; GWP
(100)
= 2140
R 404A; GWP
(100)
= 3750
This unit is hermetically sealed and the refrigerating gas load is under 3 kg.
For this reason it is not subject to the requisite of an installation booklet and periodic inspections for leakage of
the refrigerating gas
(presidential Decree no. 147 of February 15th 2006, Art. 3 and 4).
17 - Manufacturer's declaration
(Prohibition to use)
The models described above are constructed for possible assembly with other machines to form a processing line,
considered by
Directive 2006/42/CE
. Therefore the manufacturer declares that the equipment may not be used until the
line in which it is incorporated and of which it will be considered a part has been identified and declared to comply with the
terms of
Directive 2006/42/CE
and the national legislation that applies it, that is, until the machinery that is the subject of
this declaration becomes a single unit with the final processing equipment.
Summary of Contents for GEMMA 109
Page 5: ...3 FIG 8 FIG 9 Gemma FIG 10a FIG 10b FIG 11...
Page 9: ...7 RIF 7 RIF 8 RIF 9 RIF 10 RIF 11 RIF 12...
Page 62: ...60 11 12 13 14 15 16 17 18 19 20 QR 21 EAC N 108 25 01 1992 89 109 8 11 5 14 4 14 4 6 10 C 3...
Page 63: ...61 8 1 40 9 5 IEC60335 2 89 IEC60335 2 89...
Page 64: ...62 10 4 25 IEC60335 2 89 11 12 15 5 15b 5 16 5 11 13 black out 12...
Page 67: ...65...
Page 69: ...Oscartielle Spa Via Boffalora 1 A 24048 Treviolo BG 020 2011 TP TC 004 2011 010 2011...
Page 70: ......
Page 71: ......