3.3.4 Vent installation
3.3.4.1
Chimney Liner Installation
The insert must be connected to a pair of three-inch diameter listed liners suitable for use with gas.
The liners must run within the existing chimney from the vent collars on the insert, to the top of the
masonry or factory built chimney (Figures 9a, 9b and 10).
When installing this appliance into large fireplace cavities, the vents may be connected directly to
their attachments with the appliance in place. Smaller cavities may require detaching the flue collar
plate so that it can be installed separately prior to the main assembly.
Figures 9a & 9b below show the completed installations in both a masonry and a factory built
fireplace.
CO-LINEAR VENTING
MASONERY CHIMNEY
FLASHING
VENT ADAPTER
CAP
FACTORY BUILT FIREPLACE
CO-LINEAR VENTING
FACTORY BUILT CHIMNEY
FLASHING
VENT ADAPTER
CAP
Figure 9a
Figure 9b