3
1.0 INTRODUCTION
1.1 Specifications
TABLE 1
ITEM
NATURAL GAS (NG)
PROPANE (LPG)
INPUT: Hi
35,000 Btu/hr (10.25kW)
35,000 Btu/hr (10.25kW)
INPUT: Lo
17,500 Btu/hr (5.13kW)
17,500 Btu/hr (5.13kW)
MANIFOLD PRESSURE: Hi
3.5” w.c. (0.82kPa) 10.0”
w.c.
(2.49kPa)
Minimum: 5.0" w.c. (1.2 kPa)
Minimum: 11.0" w.c. (2.7 kPa)
Normal: 7.0" w.c. (1.7 kPa)
Normal: 13.3" w.c. (3.3 kPa)
GAS INLET SUPPLY
PRESSURE:
Maximum: 13.5" w.c. (3.4 kPa)
Maximum: 13.5" w.c. (3.4 kPa)
ORIFICE SIZE: @ 0-4500’
# 36 DMS (.120”) (3.05mm)
# 50 DMS (.070“) (1.78mm)
AIR SHUTTER OPENING
*CLOSED
*25% to 50% OPEN
CONTROL VALVE TYPE:
SIT 820 Nova
SIT 820 Nova
VENTING TERMINATION
Simpson « Dura-Vent »,
Security « Secure Vent » or
Selkirk « Direct Temp »
Simpson « Dura-Vent »,
Security « Secure Vent » or
Selkirk « Direct Temp »
FAN
Variable Speed (120 Volt)
Variable Speed (120 Volt)
*May vary (
±
25%) depending on the installations. Judgment of the installer is required.
Summary of Contents for SATURNA
Page 7: ...7 2 2 Lighting instructions...
Page 17: ...17 Figure 11...