10
Minimum Clearances to Combustibles :
Combustible
surface
Non-combustible
surface
No floor protection needed,
if unit is sitting at least 5
inches above the floor
Figure 5
Figure 6
10"
(255mm)
4"
(102mm)
6"
(153mm)
8"
(204mm)
8.50"
(217mm)
9.75"
(249mm)
11.25"
(287mm)
14.00"
(357mm)
12.50"
(319mm)
2"
(51mm)
D
C
B
A
G
F
COMBUSTIBLE SIDE WALL
COMBUSTIBLE TOP MANTLE
COMBUSTIBLE SHELF
FLOOR PROTECTION
COMBUSTIBLE
SIDE MANTLE
E
H
Figure 7a
Figure 7b
A- Combustible side wall to unit
B- Combustible side mantle to unit
C- Combustible top mantle to unit
D- Combustible shelf to unit
E- Minimum floor protection in front of unit
F,G,H- Minimum enclosure dimension
10”
8”
8 ½”
8 ½” to 14” (figure 7a)
0” (figure 6) or 16” (figure 5)
(figure 4)
Note:
When using paint or lacquer to finish the mantle, such paint or lacquer must be heat resistant
to prevent discoloration.