Page 30
Installation and Operation Manual - Inspire 2000 Insert
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• The insert and its stainless steel chimney liner are to be installed only within a lined masonry
chimney and masonry fireplace conforming to building codes for use with solid fuel. Do not remove
bricks or mortar from the existing fireplace when installing the insert.
8.1 Regulations Covering Insert Installation
When installed and operated as described in these instructions, this wood insert is suitable for
use in residential installations but is not intended for installation in a bedroom.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment
and the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local
code requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents
and Solid Fuel-Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be
followed in the absence of local code requirements.
This insert must be installed with a continuous chimney liner of 6" diameter extending from the
insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements
of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or Factory-built Chimneys
and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
The insert is not approved for use with a so-called “positive flue connection” to the clay tile
of a masonry chimney.
8.2 Certification Label
Since the information given on the certification label attached to the appliance always overrides
the information published in any other media, it is important to refer to it to have a safe and
compliant installation. The model and the serial number can also be found on the label.
The certification label is usually located on the side of the insert, towards the front. The faceplate
may need to be removed to see it. Therefore, it is recommended to note the insert serial number
on page 5 of this manual. It will be needed to identify the version of the appliance in the
event replacement parts or technical assistance is required. It is also recommended to
register
the warranty online
.
8.3 Masonry Fireplace Throat Damper
If the fireplace draft control system is to remain in the masonry fireplace, it must be locked
open for easy access to the chimney liner or removed entirely. If it is removed from the masonry
hearth, the notice plate 27009 must be installed in a visible place, inside the masonry hearth.
The plate can be found in the owner’s manual kit.
Figure 21: Notice Plate 27009
www.northlineexpress.com
1-877-734-2458