Page 24
Installation and Operation Manual - Inspire 2000 Insert
6.2.2 Replacement
The glass used is a ceramic glass, 4 mm thick with a dimension of 24 13/16" X 18 ½" (63 cm X
47 cm) tested to reach temperatures up to 1400º F. If the glass breaks, it must be replaced with
one having the same specification.
Tempered glass or ordinary glass will not withstand the high temperatures of this unit.
To replace the glass
(D)
, use the following
procedure
1. Remove the door from its hinges and lay it on
a soft, flat surface.
2. Remove the upper glass retainer
(A)
and the
lower glass retainer
(B)
held in place by the
screws
(C)
.
3. Remove the glass
(D)
. If it is damaged install
a new one in place. The replacement glass
must have a gasket. See the installation
procedure.
4. Reinstall the glass, being careful to centre
the glass in the door and not to over-tight
retaining screws.
5. Repeat the steps in reverse order to reinstall
the door on the insert.
A
B
D
1
2
3
C
Figure 13: Replacing the glass
6.2.3 Gasket
It is a good idea to replace the glass gasket when the door gasket is being replaced. The new
gasket is flat, adhesive-backed and made of woven fibreglass.
1. Remove the glass following the first three
steps of the «Replacement» section.
2. Remove the old gasket and clean the glass
thoroughly.
3. Peel back a section of the paper covering
the adhesive and place the gasket on a table
with the adhesive side up.
4. Stick the end of the gasket to the middle of
one edge, then press the edge of the glass
down onto the gasket, taking care that it is
perfectly centered on the gasket.
5. Cut the gasket to the required length.
Figure 14: Glass gasket
6. Pinch the gasket onto the glass in a U
shape.
7. Repeat for the other side of the glass.
Location
Length
Dimension
Top and bottom
of the glass
24 13/16"
(63 cm)
Flat 1"
(25 mm)
www.northlineexpress.com