Please read and understand this instructions manual!
This manual provides safety, installation and operation instructions which will guide you to the best
performance of your equipment.
Please keep this manual!
It includes important instructions for the safe usage of the equipment and to obtain manufacturer’s
support in case of need.
Please keep or recycle the packaging materials!
Packaging materials used in our products are designed to provide protection from transportation.
These materials are necessary in case that the equipment needs to be shipped back for service.
Damage that may occur during the shipment is not covered by the product warranty.
INTRODUCTION
- Line Interactive design
- Microprocessor control guarantees high reliability
- Frequency 50/60Hz auto-sensing
- Equipped with 2-Steps Boost & 1-Step Buck AVR to stabilize utility voltage
- Built-in DC start function enable UPS to be started up without AC power supplied
- UPS Green Mode (Energy Saving Function)
- Off-mode Charging
- Modem/Phone line surge protection
- Over/Low Voltage, Short-Circuit, and Lightning/Surge(Optional) Protection
- Built-in CCCV (Constant Current, Constant Voltage) battery Charger
CAUTION
- The UPS contains voltage that is potentially hazardous. Qualified or certified technician should proceed
all repairs and maintenance.
- The UPS has its own internal energy source (battery). The output receptacles may be active even
when the UPS is not connected to an AC supply.
- The UPS is suitable for computers and electronic equipment with substantial rectifier or capacitive
loads, not suitable for electronic equipment with significant inductive loads, such as motors &
fluorescents lamps.
- Be sure to operate within the power rating of the UPS. Below 1/2 or 1/3 of the rated power is
recommended for longer backup time & longer battery life.
- Do not place UPS near excessive humidity, under sunshine, or close to heat-emitting sources.
- If the UPS is out of order, detach the power cord and consult your dealer right away. Do not remove
cover; there is no serviceable part inside.
- The unit should be supplied by a grounded source. Do not operate the unit without a ground source.
- The socket should be installed near the equipment and be easily accessible.
- Do not plug the UPS’s power cord into itself. That will result in a safety hazard.
- A qualified technician or electrician in accordance with local electrical code should perform installation.
INSTALLATION
The UPS must be installed in a protected environment away from heat-emitting appliance such as
radiator or heater. Do not install this product where excessive moisture is present.
CAUTION
: Never connect a laser printer or plotter to the UPS. A laser printer or plotter periodically
draws significantly more power than its idle status, and may overload the UPS.
OVERVIEW
Front Panel
Rear Panel
OPERATION
5.1
When UPS is connected to city utility, but UPS is not powered on, UPS will charge battery
automatically. Please press main switch on front panel for 1 second to turn on UPS.
5.2
To turn off UPS when UPS is under AC mode, please press main switch on front panel for 4 seconds.
To turn off UPS when UPS is under battery mode, please press main switch and then UPS will shut down
completely in 10 seconds.
This UPS is designed with “Off-mode charging”, so UPS will charge battery continuously when UPS is
under AC normal. If users intend to power off UPS completely, users have to remove input power cord
from city utility.
1) On-line LED
2) Back-up LED
3) Cut-Off LED
4) Control button
5) LCD screen
6) USB charging port: 5VDC, 2.4A max.
1) AC input: Connect to input power cord
2) AC breaker
3) Back-up/AVR/Surge outlets
4) Surge outlets
5) RJ-45 port
6) Communication interface: USB port
1
2