Error messages and their correction
Heating up errors
LED lit and flashing
Heating up errors
Display text of the glass display
TEMP1 230°C
Heating error – Door closed – Heating error – Register open – Heating error – Heating time
= 61 min - Heating error – TEMP2 = 80 °C
Possible cause
• The temperature is >50 °C, it does not increase above 250 °C within 60 min�
• This means that the fire fails to start burning properly (e�g� the wood is too damp)�
• An insufficient amount of wood was inserted or replenished�
Correction
Following a power failure or after each opening and closing of the door, the control
switches into the heating up phase and the error message is acknowledged� The
combustion phases are run through again� However, when the temperature drops below
50 °C during this error message, it is also acknowledged and the control switches into the
rest phase�