General function
The heating process of an oven system is divided into various burning phases / stages:
1� Standby phase
2� Heating up phase
3� Heating phase
4� Embers phase
5� Standby phase
The ORTNER Combustion control ensures an optimal sequence of the burn-off phases
of the furnace installation� Components such as the sensor and the combustion air flap
ensure accurate control, which not only ensures ease of operation, but also maximum
efficiency�
By determining the maximum temperature in the heating phase, and a calculation based
thereon, the optimum shutoff time of the combustion air flap is defined� At this time, the
combustion air damper is automatically closed and the embers phase begins� In this phase,
an open combustion air flap would lead to an undesirable, faster cooling of the furnace
installation�
Thanks to the control, the maximum heat output is achieved, which is delivered to the
room as a soothing heat radiation�
A correct combustion
is critical in order to
enable the pleasant
prolonged heat radiation
in the room.
Shown here: ORTNER
Storage corner 09-70/40/38