The masonry heater switches to the heating phase:
Heating state
•
Is activated from a temperature of >250 °C
•
The combustion air register is open
•
The maximum temperature is stored
•
Determination of the optimal transition temperature to embers
The masonry heater switches to the heating phase >600°C:
Heating state
•
The temperature increases to >600 °C
•
The combustion air register is open
•
The maximum temperature is stored
•
Determination of the optimal transition temperature to embers
The masonry heater switches to the heating phase >600°C:
Heating state
•
The temperature drops to <600 °C
•
The combustion air register is open
The masonry heater switches to the embers or storage phase:
Embers state:
•
Is activated when the optimal transition temperature is reached
•
The combustion air register closes
•
The embers phase begins
•
Optimal heat storage is enabled
Renewed refuelling with wood in order to increase the storage duration
Door open:
•
In the event that wood should be added again for combustion, this
should be performed during the embers phase� In this case, the combustion
starts again� When refilling on the still fresh embers, only add half the wood
amount�