ORiNG DGS-7084GCP-AIO_S SERIES User Manual Download Page 137

 

DGS-7084GCP-AIO_S SERIES User’s Manual 

 

 

ORing Industrial Networking Corp

 136

Technical Specifications

 

ORing Switch Model

 

DGS-7084GCP-SS-AIO_S

 

DGS-7084GCP-MM-AIO_S

 

Physical Ports 

 

Ggiabit Combo Port with 
10/100/1000Base-T(X) and 
100/1000Base-X SFP ports 

1000Base-X SFP Port 

LC Bypass Port Type 

Single-Mode Multi-Mode 

Technology 

 

Ethernet Standards

 

IEEE 802.3 for 10Base-T 
IEEE 802.3u for 100Base-TX and 100Base-FX 
IEEE 802.3z for 1000Base-X 
IEEE 802.3ab for 1000Base-T 
IEEE 802.3x for Flow control 
IEEE 802.3ad for LACP (Link Aggregation Control Protocol ) 
IEEE 802.1D for STP (Spanning Tree Protocol) 
IEEE 802.1p for COS (Class of Service) 
IEEE 802.1Q for VLAN Tagging 
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol) 
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol) 
IEEE 802.1x for Authentication 
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol) 

MAC Table 

8k

 

Priority Queues 

Processing Store-and-Forward 

Switch Properties 

Switching latency: 7 us 
Switching bandwidth: 24Gbps 
Max. Number of Available VLANs: 4096 
IGMP multicast groups: 128 for each VLAN 
Port rate limiting: User Define 

Jumbo frame 

Up to 9.6K Bytes 

Security Features 

Device Binding security feature 
Enable/disable ports, MAC based port security 
Port based network access control (802.1x) 
VLAN (802.1Q ) to segregate and secure network traffic 
Radius centralized password management 
SNMPv3 encrypted authentication and access security 

Software Features 

STP/RSTP/MSTP (IEEE 802.1D/w/s) 
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units   
TOS/Diffserv supported 
Quality of Service (802.1p) for real-time traffic 
VLAN (802.1Q) with VLAN tagging and GVRP supported 
IGMP Snooping 
IP-based bandwidth management 
Application-based QoS management 
DOS/DDOS auto prevention 
Port configuration, status, statistics, monitoring, security 
DHCP Client/Server 

Network Redundancy

 

O-Ring  
O-Chain 
Fast Recovery Mode 
STP / RSTP compatible 
MSTP 

RS-232 Serial Console Port 

RS-232 in RJ-45 connector with console cable.    115200bps, 8, N, 1 

Switch LED indicators 

 

Power Indicator (PWR/1/2) 

Green : power LED x 3 

Summary of Contents for DGS-7084GCP-AIO_S SERIES

Page 1: ...st tr ri ia al l M Ma an na ag ge ed d G Gi ig ga ab bi it t B By yp pa as ss s E Et th he er rn ne et t S Sw wi it tc ch h U Us se er r s s M Ma an nu ua al l V Ve er rs si io on n 2 2 0 0 D De ec c...

Page 2: ...t expenses apportioned by ORing and the distributor This warranty does not cover product modifications or repairs done by persons other than ORing approved personnel and this warranty does not apply t...

Page 3: ...3 1 1 100BASE TX 10BASE T Pin Assignments 13 3 2 SFP 14 WEB Management 15 4 1 Configuration by Web Browser 15 4 1 1 About Web based Management 15 4 1 2 Basic Setting 17 4 1 2 1 System Information 17 4...

Page 4: ...65 4 1 7 4 SNMP Groups 66 4 1 7 5 SNMP Views 67 4 1 7 6 SNMP Accesses 68 4 1 8 Traffic Prioritization 69 4 1 8 1 Storm Control 69 4 1 8 2 Port QoS 70 4 1 8 3 QoS Control List 71 4 1 8 4 Queuing Counte...

Page 5: ...ing Corp 4 4 1 12 4 System Log Information 119 4 1 12 5 Cable Diagnostics 120 4 1 12 6 SFP Monitor 121 4 1 12 7 Ping 121 4 1 12 8 IPv6 Ping 122 4 1 13 Factory Defaults 123 4 1 14 System Reboot 123 Com...

Page 6: ...video privacy data and attacking IP camera NVR and controllers ORing s thunder series switch also provided advanced DOS DDOS auto prevention If there is any IP flow become big in short time ORing s t...

Page 7: ...client Supports IP based bandwidth management Supports application based QoS management Supports Device Binding security function Supports DOS DDOS auto prevention Supports DDM Digital Diagnostic Moni...

Page 8: ...0 240VAC power input for DGS 7084GCP AIO_S Operating Temperature 40 to 70o C Storage Temperature 40 to 85 o C Operating Humidity 5 to 95 non condensing Casing IP 30 8 x Gigabit combo ports and 4 x 100...

Page 9: ...ss port 3 Reset button Push the button 3 seconds for system reset 5 seconds for factory default 4 Ethernet switch LED Status LED for PWR When the any PWR ON the green led will be light on LED for PWR1...

Page 10: ...dicator 10 1000Base X SFP Port 11 LED for SFP ports link status 2 2 Back Panel The back panel of DGS 7084GCP AIO_S is shown as below 1 Power socket of power input for AC 100V 240V 50 60Hz 2 Relay outp...

Page 11: ...DGS 7084GCP AIO_S SERIES User s Manual ORing Industrial Networking Corp 10...

Page 12: ...power module is in PWR UP state the green LED lights on Blinking When the system is upgrading firmware PWR 1 2 Green On When the PWR links the green led will be light on R M Green On When the system...

Page 13: ...DGS 7084GCP AIO_S SERIES User s Manual ORing Industrial Networking Corp 12 LINK ACT Green On Port link up Blinking Data transmitted...

Page 14: ...100 ohm UTP UTP 100 m 328 ft RJ 45 1000BASE TX Cat 5 Cat 5e 100 ohm UTP UTP 100 m 328ft RJ 45 3 1 1 100BASE TX 10BASE T Pin Assignments The DGS 7084GCP AIO_S switch support auto MDI MDI X operation Y...

Page 15: ...represent the polarity of the wires that make up each wire pair 3 2 SFP The Switch has fiber optical ports with SFP connectors The fiber optical ports are in multi mode 0 to 550M 850 nm with 50 125 m...

Page 16: ...ement function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By d...

Page 17: ...Networking Corp 16 3 The login screen appears 4 Key in the username and password The default username and password is admin 5 Click Enter or OK button then the main interface of the Web based managem...

Page 18: ...d domain name A domain name is a text string drawn from the alphabet A Z a z digits 0 9 minus sign No space characters are permitted as part of a name The first character must be an alpha character An...

Page 19: ...to access the web pages or log in from CLI Label Description Old Password Enter the current system password If this is incorrect the new password will not be set New Password The system password The...

Page 20: ...ess that the network is using If DHCP client function is enabling you do not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be display in t...

Page 21: ...omplete auto configuration can be significantly longer Address Provide the IPv6 address of this switch IPv6 address is in 128 bit records represented as eight fields of up to four hexadecimal digits w...

Page 22: ...h field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand way of representing multiple 16 bit groups of contiguous zeros but it can only appear once It...

Page 23: ...Enable SSH mode operation Disabled Disable SSH mode operation Click to save changes Click to undo any changes made locally and revert to previously saved values 4 1 2 7 LLDP LLDP Configuration This p...

Page 24: ...ides a status overview for all LLDP neighbors The displayed table contains a row for each port on which an LLDP neighbor is detected The columns hold the following information Label Description Local...

Page 25: ...address Click to refresh the page immediately Check this box to enable an automatic refresh of the page at regular intervals LLDP Statistics This page provides an overview of all LLDP traffic Two typ...

Page 26: ...as Too Many Neighbors in the LLDP standard LLDP frames require a new entry in the table when the Chassis ID or Remote Port ID is not already contained within the table Entries are removed from the ta...

Page 27: ...6 regular intervals 4 1 2 8 Backup Restore Configuration You can save view or load the switch configuration The configuration file is in XML format with a hierarchy of tags 4 1 2 9 Firmware Update Thi...

Page 28: ...erver 4 1 3 1 Setting The system provides with DHCP server function Enable the DHCP server function the switch system will be a DHCP server 4 1 3 2 DHCP Dynamic Client List When the DHCP server functi...

Page 29: ...IP assigning the system will assign the IP address that has been assigned before in the connected device 4 1 4 Port Setting 4 1 4 1 Port Control This page displays current port configurations Ports ca...

Page 30: ...This setting is related to the setting for Configured Link Speed Maximum Frame Enter the maximum frame size allowed for the switch port including FCS The allowed range is 1518 bytes to 9600 bytes Exc...

Page 31: ...to 500 1000000 when the Policer Unit is kbps and it is restricted to 1 1000 when the Policer Unit is Mbps Policer Unit Configure the unit of measure for the port policer rate as kbps or Mbps The defa...

Page 32: ...y default Source MAC Address is enabled Destination MAC Address The Destination MAC Address can be used to calculate the destination port for the frame Check to enable the use of the Destination MAC A...

Page 33: ...s there is no aggregation Only one group ID is valid per port Port Members Each switch port is listed for each group ID Select a radio button to include a port in an aggregation or clear the radio but...

Page 34: ...dio button to include a port in an aggregation or clear the radio button to remove the port from the aggregation By default no ports belong to any aggregation group Only full duplex ports can join an...

Page 35: ...scription Aggr ID The Aggregation ID associated with this aggregation instance For LLAG the id is shown as isid aggr id and for GLAGs as aggr id Partner System ID The system ID MAC address of the aggr...

Page 36: ...is down Backup means that the port could not join the aggregation group but will join if other port leaves Meanwhile it s LACP status is disabled Key The key assigned to this port Only ports with the...

Page 37: ...port number LACP Transmitted Shows how many LACP frames have been sent from each port LACP Received Shows how many LACP frames have been received at each port Discarded Shows how many unknown or ille...

Page 38: ...on Active Enable Loop Guard function Port State Guarding This port is protected against looping Locked This port has been locked to avoid looping 4 1 5 Redundancy 4 1 5 1 O Ring Ring is the most power...

Page 39: ...p link Set a port as coupling port The coupled four ports of four switches will be run at active backup mode Dual Homing Mark to enable Dual Homing By selecting Dual Homing mode Ring will be connected...

Page 40: ...abling the O Chain function 1st Ring Port Choosing the port which connect to the ring 2nd Ring Port Choosing the port which connect to the ring Edge Port In the O Chain application the head and tail o...

Page 41: ...of the information transmitted by the Bridge when it is the Root Bridge Valid values are in the range 6 to 40 seconds and MaxAge must be FwdDelay 1 2 Maximum Hop Count This defines the initial value...

Page 42: ...STI mapping configuration in order to share spanning trees for MSTI s Intra region The name is at most 32 characters Configuration Revision The revision of the MSTI configuration named above This must...

Page 43: ...iority configurations and possibly change them as well Label Description MSTI The bridge instance The CIST is the default instance which is always active Priority Controls the bridge priority Lower nu...

Page 44: ...active topology of the network Lower path cost ports are chosen as forwarding ports in favor of higher path cost ports Valid values are in the range 1 to 200000000 Priority Controls the port priority...

Page 45: ...r to prevent bridges external to a core region of the network causing address flushing in that region possibly because those bridges are not under the full control of the administrator or is the physi...

Page 46: ...2 1D recommended values Using the Specific setting a user defined value can be entered The path cost is used when establishing the active topology of the network Lower path cost ports are chosen as fo...

Page 47: ...he currently elected root bridge Root Port The switch port currently assigned the root port role Root Cost Root Path Cost For the Root Bridge this is zero For all other Bridges it is the sum of the Po...

Page 48: ...t BackupPort RootPort DesignatedPort State The current STP port state of the CIST port The port state can be one of the following values Blocking Learning Forwarding Uptime The time since the bridge p...

Page 49: ...rded Unknown The number of unknown Spanning Tree BPDU s received and discarded on the port Discarded Illegal The number of illegal Spanning Tree BPDU s received and discarded on the port Click to refr...

Page 50: ...ch can be monitored and modified here Up to 64 VLANs are supported This page allows for adding and deleting VLANs as well as adding and deleting port members of each VLAN Label Description Delete Chec...

Page 51: ...tack switch units but with no port members A VLAN without any port members on any stack unit will be deleted when you click Save The button can be used to undo the addition of new VLANs Example Portba...

Page 52: ...IES User s Manual ORing Industrial Networking Corp 51 3 VLAN Port 1 Configuration Mode specific ID 50 For egress port 1 VLAN Membership Configuration setting port 2 VID 50 2 VLAN Port 2 Configuration...

Page 53: ...ustrial Networking Corp 52 3 VLAN Port 2 Configuration Mode specific ID 50 any packet can enter egress port 802 1Q Access port Setting For ingress port 1 VLAN Membership Configuration setting port VID...

Page 54: ...king Corp 53 1 VLAN Port Configuration Mode specific ID 50 For egress port 1 VLAN Membership Configuration setting port VID 50 2 VLAN Port Configuration Disable VLAN Aware 3 VLAN Port Configuration Mo...

Page 55: ...DGS 7084GCP AIO_S SERIES User s Manual ORing Industrial Networking Corp 54 802 1Q Trunk port setting multi tag For ingress port 1 VLAN Membership Configuration setting port VID 11 22 33...

Page 56: ...strial Networking Corp 55 2 VLAN Port Configuration Enable VLAN Aware 3 VLAN Port Configuration Mode specific ID 11 when entering packet is untagged frame added tag 11 When entering the tagged frame o...

Page 57: ...DGS 7084GCP AIO_S SERIES User s Manual ORing Industrial Networking Corp 56 For egress port 1 VLAN Membership Configuration setting port VID 11 22 33 2 VLAN Port Configuration Enable VLAN Aware...

Page 58: ...ser s Manual ORing Industrial Networking Corp 57 3 VLAN Port Configuration Mode none egress port can receive tag 11 22 33 packet In addition ony tag 11packet can enter egress port QinQ VLAN Setting in...

Page 59: ...Manual ORing Industrial Networking Corp 58 For ingress port Port 1 1 VLAN Membership Configuration setting port 1 2 3 VID 50 2 VLAN Port Configuration Disable Port 1 VLAN Aware 3 VLAN Port Configurat...

Page 60: ...Ring Industrial Networking Corp 59 For egress port Port 2 1 VLAN Membership Configuration setting port VID 50 2 VLAN Port Configuration Enable Port 2 3 VLAN Aware 3 VLAN Port Configuration Mode none o...

Page 61: ...Private VLANs Label Description Delete Check to delete the entry It will be deleted during the next save Private VLAN ID Indicates the ID of this particular private VLAN MAC Address The MAC address fo...

Page 62: ...can be used to undo the addition of new Private VLANs Label Description Port Members A check box is provided for each port of a private VLAN When checked port isolation is enabled for that port When...

Page 63: ...characters from 33 to 126 The field only suits to SNMPv1 and SNMPv2c SNMPv3 is using USM for authentication and privacy and the community string will associated with SNMPv3 communities table Write Com...

Page 64: ...fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand way of representing multiple 16 bit groups of contiguous zeros but it can only appear once It also used a follow...

Page 65: ...ng must contain an even number between 10 and 64 hexadecimal digits but all zeros and all F s are not allowed Trap Security Name Indicates the SNMP trap security name SNMPv3 traps and informs using US...

Page 66: ...own snmpEngineID value The value can also take the value of the snmpEngineID of a remote SNMP engine with which this user can communicate In othe words if user engine ID equal system engine ID then i...

Page 67: ...content is the ASCII characters from 33 to 126 Privacy Protocol Indicates the privacy protocol that this entry should belong to Possible privacy protocols are None None privacy protocol DES An option...

Page 68: ...elete the entry It will be deleted during the next save View Name A string identifying the view name that this entry should belong to The allowed string length is 1 to 32 and the allowed content is th...

Page 69: ...cepted any security model v1 v2c usm v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Level Indicates the security model that this entry should belong to Poss...

Page 70: ...The configuration indicates the permitted packet rate for unicast multicast or broadcast traffic across the switch Note Frames which are sent to the CPU of the switch are always limited to aproximatel...

Page 71: ...as VLAN ID UDP TCP port IPv4 IPv6 DSCP or Tag Priority Frames not matching any of the QCEs are classified to the default QoS class for the port Port QoS Configuration Label Description Port A check bo...

Page 72: ...to classify certain frames to a specific QoS class This classification can be based on parameters such as VLAN ID UDP TCP port IPv4 IPv6 DSCP or Tag Priority Frames not matching any of the QCEs are cl...

Page 73: ...Modification Buttons You can modify each QCE in the table using the following buttons Inserts a new QCE before the current row Edits the QCE Moves the QCE up the list Moves the QCE down the list Delet...

Page 74: ...ickly Label Description Set up Port Policies Group ports into several types according to different QCL policies Set up Typical Network Application Rules Set up the specific QCL for different typical n...

Page 75: ...GMP Snooping IGMP Querier Enable the IGMP Querier in the VLAN The Querier will send out if no Querier received in 255 seconds after IGMP Querier Enabled Each Querier s interval is 125 second and it wi...

Page 76: ...ntry Querier Status Show the Querier status is ACTIVE or IDLE Querier Receive The number of Transmitted Querier V1 Reports Receive The number of Received V1 Reports V2 Reports Receive The number of Re...

Page 77: ...rejected Label Description Port Port number of remote client IP Address IP address of remote client Keeps this field 0 0 0 0 means Any IP Web Check this item to enable Web management interface Telnet...

Page 78: ...s the device is still alive Lost Reply Lost ping reply from device that means the device might have been hanged Stream Check Active Enable Disable Stream Check When enabled switch will detect the stre...

Page 79: ...figuration Alias IP Address This page provides Alias IP Address related configuration Some device might have more IP addresses than one you could specify the other IP address here Label Description Al...

Page 80: ...h action Label Description Link Change Disable and enable port Only log it Only sent log to log server Shunt Down the Port Disable this port DDoS Prevention This page provides DDOS Prevention related...

Page 81: ...a range from low to high If the socket number is only one please fill the same number in low field and high field Filiter If packet type is UDP or TCP please choose the socket direction Destination So...

Page 82: ...tion Device Type Indicates the type of device Possible types are No specification IP Camera IP Camera IP Phone IP Phone Access Point Access Point PC PC PLC PLC Network Video Recorder Network Video Rec...

Page 83: ...iption Mode Enable Disable stream monitor of the port Action Indicates the action when stream getting low Possible actions are Do nothing Log it Just log the event 4 1 10 3 ACL 4 1 10 3 1 Port Configu...

Page 84: ...s are copied to The allowed values are Disabled or a specific port number The default value is Disabled Logging Specify the logging operation of this port The allowed values are Enabled Frames receive...

Page 85: ...hen select the frame type Different parameter options are displayed depending on the frame type that you selected A frame that hits this ACE matches the configuration that is defined here Label Descri...

Page 86: ...that the rate limiter operation is disabled Port Copy Frames that hit the ACE are copied to the port number specified here The allowed range is the same as the switch port number range Disabled indic...

Page 87: ...his ACE Any No DMAC filter is specified DMAC filter status is don t care MC Frame must be multicast BC Frame must be broadcast UC Frame must be unicast Specific If you want to filter a specific destin...

Page 88: ...specific IP protocol filter with this ACE choose this value A field for entering an IP protocol filter appears ICMP Select ICMP to filter IPv4 ICMP protocol frames Extra fields for defining ICMP para...

Page 89: ...ons flag is set must not be able to match this entry Yes IPv4 frames where the options flag is set must be able to match this entry Any Any value is allowed don t care SIP Filter Specify the source IP...

Page 90: ...e set to ARP RARP Frame must have ARP RARP opcode set to RARP Other Frame has unknown ARP RARP Opcode flag Request Reply Specify the available ARP RARP opcode OP flag for this ACE Any No ARP RARP OP f...

Page 91: ...s can hit the action according to their sender hardware address field SHA settings 0 ARP frames where SHA is not equal to the SMAC address 1 ARP frames where SHA is equal to the SMAC address Any Any v...

Page 92: ...on according to their ARP RARP protocol address space PRO settings 0 ARP RARP frames where the PRO is equal to IP 0x800 must not match this entry 1 ARP RARP frames where the PRO is equal to IP 0x800 m...

Page 93: ...e that hits this ACE matches this TCP UDP source value TCP UDP Destination Filter Specify the TCP UDP destination filter for this ACE Any No TCP UDP destination filter is specified TCP UDP destination...

Page 94: ...SH value for this ACE 0 TCP frames where the PSH field is set must not be able to match this entry 1 TCP frames where the PSH field is set must be able to match this entry Any Any value is allowed don...

Page 95: ...Port Policies Group ports into several types according to different ACL policies Set up Typical Network Application Rules Set up the specific ACL for different typical network application access contr...

Page 96: ...special 802 1X frames known as EAPOL EAP Over LANs frames EAPOL frames encapsulate EAP PDUs RFC3748 Frames sent between the switch and the RADIUS server is RADIUS packets RADIUS packets also encapsula...

Page 97: ...xx that is a dash is used as separator between the lower cased hexadecimal digits The switch only supports the MD5 Challenge authentication method so the RADIUS server must be configured accordingly W...

Page 98: ...n is only useful if the RADIUS server configuration has changed It does not involve communication between the switch and the client and therefore doesn t imply that a client is still present on a port...

Page 99: ...from it If on the other hand the client transmits a frame before the second half of the age period expires the switch will consider the client alive and leave it authenticated Therefore an age period...

Page 100: ...undertake one of the following values Disabled 802 1X and MAC based authentication is globally disabled Link Down 802 1X or MAC based authentication is enabled but there is no link on the port Author...

Page 101: ...ady used all available state machines Restart Two buttons are available for each row The buttons are only enabled when authentication is globally enabled and the port s Admin State is Auto or MAC Base...

Page 102: ...n of the individual states Last Source The source MAC address carried in the most recently received EAPOL frame for port based authentication and the most recently received frame from a new client for...

Page 103: ...box to select which port details to be displayed Label Description EAPOL Counters These counters are not available for MAC based ports Supplicant frame counter statistics There are seven receiving fr...

Page 104: ...counters between port and MAC based authentications as shown below Last Supplicant Client Info For MAC based ports this section is embedded in the backend server counter s section Information about th...

Page 105: ...hown in the right most backend server counters table above If no clients are attached it shows No clients attached State Shows whether the client is authorized or unauthorized As long as the backend s...

Page 106: ...ed authentication servers are alive the local user database is used for authentication This is only possible if the Authentication Method is set to something else than none or local Click to save chan...

Page 107: ...e server is disabled Not Ready The server is enabled but IP communication is not yet up and running Ready The server is enabled IP communication is up and running and the RADIUS module is ready to acc...

Page 108: ...running Ready The server is enabled IP communication is up and running and the RADIUS module is ready to accept accounting attempts Dead X seconds left Accounting attempts were made to this server bu...

Page 109: ...Networking Corp 108 Label Description Packet Counters RADIUS authentication server packet counter There are seven receive and four transmit counters Other Info This section contains information about...

Page 110: ...ve receive and four transmit counters Other Info This section contains information about the state of the server and the latest 4 1 11 Warning 4 1 11 1 System Warning 4 1 11 1 1 SYSLOG Setting The SYS...

Page 111: ...net Please refer to RFC 821 Simple Mail Transfer Protocol System Warning SMTP Setting interface The following table describes the labels in this screen Label Description E mail Alarm Enable Disable tr...

Page 112: ...enable system event warning method you wish to choose Please note that the checkbox cannot be checked when SYSLOG or SMTP is disabled System Warning Event Selection interface The following table desc...

Page 113: ...vate the configurations Help Show help file 4 1 12 Monitor and Diag 4 1 12 1 MAC Table 4 1 12 1 1 Configuration The MAC Address Table is configured on this page Set timeouts for entries in the dynamic...

Page 114: ...settings Label Description Auto Learning is done automatically as soon as a frame with unknown SMAC is received Disable No learning is done Secure Only static MAC entries are learned all other frames...

Page 115: ...s per page input field When first visited the web page will show the first 20 entries from the beginning of the MAC Table The first displayed will be the one with the lowest VLAN ID and the lowest MAC...

Page 116: ...ID of the entry Port Members The ports that are members of the entry 4 1 12 2 Port Statistic 4 1 12 2 1 Traffic Overview This page provides an overview of general traffic statistics for all switch po...

Page 117: ...rs entries starting from the current entry ID Flushes all counters entries 4 1 12 2 2 Detailed Statistics This page provides detailed traffic statistics for a specific switch port Use the port select...

Page 118: ...CRC Rx Jabber The number of long 2 frames received with invalid CRC Rx Filtered The number of received frames filtered by the forwarding process Tx Drops The number of frames dropped due to output buf...

Page 119: ...not mirrored Tx only Frames transmitted from this port are mirrored to the mirror port Frames received are not mirrored Disabled Neither frames transmitted nor frames received are mirrored Enabled Fra...

Page 120: ...vel of the system log All All levels Time The time of the system log entry Message The MAC Address of this switch Check this box to enable an automatic refresh of the page at regular intervals Updates...

Page 121: ...tically and you can view the cable diagnostics results in the cable status table Note that VeriPHY is only accurate for cables of length 7 140 meters 10 and 100 Mbps ports will be linked down while ru...

Page 122: ...4 1 12 7 Ping This page allows you to issue ICMP PING packets to troubleshoot IP connectivity issues After you press 5 ICMP packets are transmitted and the sequence number and roundtrip time are disp...

Page 123: ...132 20 icmp_seq 4 time 0ms Sent 5 packets received 5 OK 0 bad You can configure the following properties of the issued ICMP packets Label Description IP Address The destination IP Address Ping Size T...

Page 124: ...etained Label Description Click to reset the configuration to Factory Defaults Click to return to the Port State page without resetting the configuration 4 1 14 System Reboot You can reset the stack s...

Page 125: ...n use console or telnet to management switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before Configuring by RS 232 serial console use a DB9 M to DB9 F cable to connect the S...

Page 126: ...DGS 7084GCP AIO_S SERIES User s Manual ORing Industrial Networking Corp 125 Step 2 Input a name for new connection Step 3 Select to use COM port number...

Page 127: ...e 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appear Use the keyboard to enter the Username and Password The same with the password f...

Page 128: ...254 User Name root Password root Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the switch from the Windows Run command or from the MS DOS prompt as below...

Page 129: ...r Groups System System Configuration all port_list Reboot Restore Default keep_ip Contact contact Name name Location location Description description Password password Username username Timezone offse...

Page 130: ...S server_index enable disable ip_addr_string secret server_port Client console telnet ssh web none local radius enable disable Statistics server_index Port Port Configuration port_list State port_list...

Page 131: ...FwdDelay delay bpduFilter enable disable bpduGuard enable disable recovery timeout CName config name integer Status msti port_list Msti Priority msti priority Msti Map msti clear Msti Add msti vid Po...

Page 132: ...Timeout eapol_timeout Statistics port_list clear eapol radius Clients port_list all client_cnt Agetime age_time Holdtime hold_time IGMP IGMP Configuration port_list Mode enable disable State vid enab...

Page 133: ...t_list auto disable secure Dump mac_max mac_addr vid Statistics port_list Flush VLAN VLAN Configuration port_list Aware port_list enable disable PVID port_list vid none FrameType port_list all tagged...

Page 134: ...enable disable packet_rate Storm Multicast enable disable packet_rate Storm Broadcast enable disable packet_rate ACL ACL Configuration port_list Action port_list permit deny rate_limiter port_copy lo...

Page 135: ...urity Name security_name Engine ID engineid Community Add community ip_addr ip_mask Community Delete index Community Lookup index User Add engineid user_name MD5 SHA auth_password DES priv_password Us...

Page 136: ...User s Manual ORing Industrial Networking Corp 135 Access Lookup index Firmware Firmware Load ip_addr_string file_name fault Fault Alarm PortLinkDown port_list enable disable Alarm PowerFailure pwr1...

Page 137: ...erties Switching latency 7 us Switching bandwidth 24Gbps Max Number of Available VLANs 4096 IGMP multicast groups 128 for each VLAN Port rate limiting User Define Jumbo frame Up to 9 6K Bytes Security...

Page 138: ...nable mode Bypass normal status indicate Normal Green indicate bypass function in normal disable mode Fault contact Relay Relay output to carry capacity of 1A at 24VDC Power Redundant Input power Dual...