DGS-7084GCP-AIO_S SERIES User’s Manual
ORing Industrial Networking Corp
120
4.1.12.5 Cable Diagnostics
This page is used for running the VeriPHY Cable Diagnostics.
Press
to run the diagnostics. This will take approximately 5 seconds. If all
ports are selected, this can take approximately 15 seconds. When completed, the page
refreshes automatically, and you can view the cable diagnostics results in the cable
status table. Note that VeriPHY is only accurate for cables of length 7 - 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore,
running VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop
responding until VeriPHY is complete.
Label
Description
Port
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status
Port: Port number.
Pair: The status of the cable pair.
Length: The length (in meters) of the cable pair.