![Orientalmotor OPX-2A Operating Manual Download Page 30](http://html1.mh-extra.com/html/orientalmotor/opx-2a/opx-2a_operating-manual_1651201030.webp)
8 Parameter mode
−
30
−
Common parameters
Initial
value
Setting range
Description
1 0:
Disable
1: Enable
Sets whether to enable
or disable software
overtravel detection
using soft limits.
8,388,607
−
8,388,608 to
+8,388,607
steps
Sets the value of soft
limit in + direction.
−
8,388,608
−
8,388,608 to
+8,388,607
steps
Sets the value of soft
limit in
−
direction.
0 0:
Signed
1: Absolute
Sets the display method
of monitored speed in
the data setter.
1 0:
Immediate
stop
1: Decelerate
stop
Sets how to stop the
motor when a
communication timeout
occurs.
0 0:
Function
disable
0.01 to 9.99 sec
Sets the receive period
for RS-485
communication.
50
0 to 1000 ms
Sets the response
period for RS-485
communication.
0.10
0.01 to 9.99 sec
Sets the receive monitor
period for RS-485
communication.
Software overtravel
Software overtravel
Positive software limit
Negative software limit
Display mode of the
data setter speed
Communication timeout
action
RS-485 receive period
RS-485 response
interval
RS-485 receive
monitoring
Stepout detection action
through the items.
Use
to navigate
0
0: No operation
1: Warning
2: Alarm
Sets the operation to be
performed when the
deviation between the
command position and
encoder counter value
reaches the stepout
detection band.
Summary of Contents for OPX-2A