8 Parameter mode
−
24
−
Note
•
If the value you have input is outside the setting range, “Error” will be displayed for
1 second. If this error display appears, input a different value that falls within the
setting range.
•
If the
key on the
OPX-2A
is pressed while internal processing is being
performed via RS-485 communication, the top screen will not change to any of its
sub-screens and “mEm-bUSY” will be shown on the display. Be sure to wait until all
internal processing is completed, before pressing the
key.
8.3 Setting
example
Pressing the
key in the parameter item screen enables parameter setting.
How a parameter is set are explained below.
Example: Assign the ZSG output to the OUT1 output
1.
Use the
key to select the
parameter mode.
The “PAR” LED is lit.
2.
Press the
key.
The display changes to the application
parameter screen.
3.
Press the
key.
The display changes to the START input
mode parameter screen.
4.
Use the
key to select “6”.
The display changes to the OUT1 signal
mode selection parameter screen.
5.
Press the
key.
The display changes to the screen where
you can set the function of the OUT1
output.
6.
Press the
key and then use
the
keys to
select “10”.
“
10” indicates the ZSG output.
7.
Press the
key again.
The entered value is set and the display
returns to the screen where you can set
the function of the OUT1 output.
START input mode parameter
OUT1 signal mode selection parameter
OUT1 signal mode selection parameter
Set the OUT1 output to "10"
Confirm the value (blinking display)
I/O parameter
Application parameter
Top screen of the parameter mode
decrease the value.
Use
to increase/
through the digits.
Use
to navigate
Note
If the value you have input is outside the setting range, “Error” will be displayed for 1
second. If this error display appears, input a different value that falls within the setting
range.