6 Monitor mode
−
16
−
•
How to clear all alarm records
You can clear all alarm records at once.
1.
While an alarm is displayed, press the
key to move to the lower level.
2.
Press the
key and select the alarm record clear screen.
3.
Press the
key.
All alarm records are cleared.
Alarm record 1 (latest)
Present alarm
Alarm record 1 (latest)
Alarm record 2
Alarm record 10 (oldest)
Alarm reset
Clear alarm records
Alarm is being reset (blinking display)
Alarm records are being
cleared (blinking display)
to navigate
Use
through the items.
∗
If operations are limited by the edit lock function (p.7), the screen text in gray is not shown.
•
Alarm code list
Code Alarm
name
Resetting on
the
OPX-2A
Number of times the driver’s
ALARM LED blinks
10 Overflow
Possible
4
41
EEPROM error
Not possible
9
21 Overheat
Possible
2
22 Overvoltage
Not
possible
3
60
±
LS both sides active
Possible
7
61
Reverse limit sensor connection
Possible
7
62
Home seeking error
Possible
7
63 No
HOMES
Possible 7
64
TIM, Z, SLIT input error
Possible
7
66 Overtravel
Possible
7
67 Software
overtravel
Possible
7
6A
Home seeking offset error
Possible
7
70
Invalid operation data
Possible
7
84
RS-485 communication error
Not possible
7
85
RS-485 communication timeout
Possible
7