- 4 -
3 Preparation
3.1 Connection and Switch Setting
Driver
24 VDC
Power supply
PC
USB
Driver connector (26 pins)
+
-
For all drivers except
AR
(
LSD
)
/NX
Series
Memo
When the
LSD
driver is used, refer to the instructions indicated as the "
AR
Series" in
this startup manual.
1.
Set the driver pulse Input mode to 1 pulse mode.
See the driver manual for information on how to set.
2.
Connect Pulse/Direction signals to the driver connector
14:PLS-/CW-
15:DIR-/CCW-
1:PLS+/CW+
2:DIR+/CCW+
Pin assignment for Driver connector (26 pins)
∗
See the driver manual for pulse input circuit and pin assignment on the driver.
The following example shows photo-coupler pulse input type drivers. (1-pulse mode)
SCX11
DIR-
DIR+
PLS-
PLS+
PLS+/CW +
PLS-/CW -
DIR+/CCW +
DIR-/CCW -
Driver
14
2
15
1
Memo
The 5/24 V and SOURCE/SINK switch settings are not required for test operation.
After the test operation, turn the power off, and set those switches according to the
Operating Manual.
3.
Connect the 24 VDC power supply
Strip the cable insulation by 10mm. Push down the spring (orange) of the connector with the
flat-tip screwdriver to open a terminal point, and insert the cable.