Preparation
−7−
Name
Description
Ref.
POWER LED (Green)
This LED is lit while the power is input.
−
ALARM LED (Red)
This LED will blink or illuminate steadily when an alarm or
MECHATROLINK-
Ⅲ
communication error has generated.
C-DAT LED (Green)
This LED is lit while transmitting and receiving data via RS-485
communication.
−
C-ERR LED (Red)
This LED is lit when an error has occurred via RS-485 communication.
−
CONT LED (Green)
This LED is lit while a connection is established.
−
ERR LED (Red)
This LED is lit when the MECHATROLINK-
Ⅲ
communication error has
generated.
RS-485 communication transmission
rate setting switch (SW1)
Sets the transmission rate of RS-485 communication.
Factory setting: 7 (625 kbps)
Data edit connector (CN3)
Connects a PC in which the
MEXE02
has been installed, or an accessory
OPX-2A
(sold separately).
Power supply connector (CN1)
Connects a 24 VDC power supply.
MECHATROLINK-
Ⅲ
station address
setting switches (STATION No.×1, ×10)
Sets the station address in the 03h to EFh range.
Factory setting: 61h (×10=6, ×1=1)
×10: Sets the upper of the station address
×1: Sets the lower of the station address
Operation mode setting switch
(SW2-Nos.1 to 3)
Sets the operation mode.
•
SW2-No.1: Sets the remote I/O occupied size.
Factory setting: OFF (16 bit mode)
•
SW2-No.2, No.3: Sets the number of transmission bytes.
Factory setting: No.2=OFF, No.3=ON (32 bytes)
LINK1 LED (Green)
LINK2 LED (Green)
These LEDs are lit while MECHATROLINK-
Ⅲ
communication is properly
connected.
−
MECHATROLINK-
Ⅲ
communication
connector (CN2-1, CN2-2)
Connects the MECHATROLINK-
Ⅲ
communication cable.
RS-485 communication connector
(CN6)
Connects the RS-485 communication cable.