Connection
−13−
5.4 Connecting the MECHATROLINK-
Ⅲ
communication cable
Connect the MECHATROLINK-
Ⅲ
communication cable to
the MECHATROLINK-
Ⅲ
communication connector (CN2-1
or CN2-2) of the
NETC01-M3
. For the MECHATROLINK-
Ⅲ
communication cable, use a dedicated cable with connector.
Other MECHATRLINK-
Ⅲ
communication compatible products
can be connected to the vacant connector.
MECHATROLINK-
䊢
communication connector
(CN2-1)
MECHATROLINK-
䊢
communication cable
5.5 Connecting the data setter
Connect the
OPX-2A
cable or communication cable for
the data setting software to the data edit connector (CN3)
on the
NETC01-M3
.
Data edit connector (CN3)
OPX-2A
cable or communication
cable for the data setting software
The power supply connector (CN1), MECHATROLINK-
Ⅲ
communication connector (CN2-
1, CN2-2), data edit connector (CN3) and RS-485 communication connector (CN6) of
the
NETC01-M3
are not electrically insulated. When grounding the positive terminal
of the power supply, do not connect any equipment (PC, etc.) whose negative terminal
is grounded. Doing so may cause the
NETC01-M3
and these equipment to short,
damaging both.