Details of command
−43−
Monitor (remote register)
1)
Specify the register address number.
2)
Check the register address number response.
3) Turn the TRIG from OFF to ON. The selected monitor command is executed.
4) After checking the TRIG_R was turned from OFF to ON, check the command code response and DATA
response.
The DATA response value is updated while the TRIG is ON.
5) Turn the TRIG from ON to OFF, and check that the TRIG_R was turned from ON to OFF.
When monitoring the "command position"
TRIG
0001h
0001h
0 s or more
0 s or more
2063h
2063h
100 (0064h)
0 (0000h)
(TM+TS)×2
(TM+TS)×2
(TM+TS)×2
200 (00C8h)
OFF
ON
TRIG_R
OFF
ON
DATA
TM+TS
TM+TS
DATA response
Command code
Register address number
response
Command code response
Register address number
[
NETC01-M3
to master]
[Master to
NETC01-M3
]
Summary of Contents for NETC01-M3