background image

fig.10

When installing tools directly into the blower or suction port
without the using hose, the tool adapter tube must be used.

Adjustable Extension Wand

fig. 11

To adjust extension wand, press release button and pull
inner tube to desired length. Tube will lock when button
is released. To shorten length, press release button and
push inner tube.

For Easy Cord Storage

fig. 12

Wrap cord around the cord wrap and cord dump located on
bottom of the canister. To release cord, twist the cord dump.

Blower Port

fig. 13

Remove HEPA Filter cover and filter at back of machine.
Firmly insert flexible hose into exhaust port.

Maintenance

WARNING: Unplug cord from electrical 
outlet before servicing.

Changing the Filter Bag

fig. 14

Use only genuine ORECK XL filter bags. Stand unit on
its back. Twist knob counterclockwise to release and lift
out front plate.

fig. 15

Remove used bag and insert fresh bag. The cardboard
rim fits smoothly into the recessed top. Align tabs on
front plate with slots in housing and replace the front
plate. Close unit by turning knob clockwise.

fig. 16 IMPORTANT:

The white bag gasket glued in the housing

must be in place or unit will not operate properly.
Replace gasket if needed.

NOTE:

The disposable inner filter bag must be replaced once a
month even if it 

is not

full. Change it more often if it is

used in extremely dirty areas. 

Increase the cleaning

power of your vacuum by changing the bag often.

Replacing the Micro Filter

Remove filter bag by following the 

Changing the Filter Bag

instructions.

fig. 17

Remove old micro filter from bottom inside unit.  Replace
with new filter. 

NOTE:

A replacement filter is supplied in each package of 12
ORECK XL filter bags or you may order filters separately.

Using a HEPA-Filter and Scent Cartridge

fig. 18

Remove HEPA Filter cover at back of machine by
pressing down in top slot and folding back the cover. Lift
cover to remove.

fig. 19

Insert Fresh Air

®

Scent Cartridge on tab located in center

of the filter cover.

fig. 20

Place the HEPA Filter in the filter cover.

fig. 18

Replace the HEPA Filter assembly on the canister by
placing the bottom lip of the cover in the inside slot of
the canister and closing the cover until the top latch is
locked.

NOTE:

It is recommended to replace the scent cartridge when
the inner filter bag is replaced. 

Replace the HEPA filter every 

6 months

. Replace more

often if vacuum is used to pick up fine particles or in
extremely dirty areas.

Assembly

IMPORTANT:

DO NOT

REMOVE the
dirt retaining
flap attached on
the back of the
front plate. It
must be left in
place for the
unit to operate
properly and to
ensure cleaning
effectiveness.

Attach Caddy and Insert Tools

fig. 1

Locate caddy clip slots at top rear corners of canister
handle. Place appliance on firm, non-slip surface or hold in
your lap. Grasp handle firmly. Place one of caddy clip tabs
inside slot on one side of handle and stretch the other tab
around handle until the opposite tab inserts in slot. 

fig. 2

Insert crevice tool, brush and fabric tool into caddy in
spaces provided.

fig. 3

Caddy will lift up 90° to allow access to the HEPA filter
cover.

Attach Shoulder Strap

fig. 4

Clamp one end of shoulder strap in front slot located at
front of handle.

fig. 5

Clamp opposite end of shoulder strap in slot at back of
handle. 

fig. 6

Adjust length by pulling strap through clip.

IMPORTANT: 

Before using shoulder strap, pull both ends to be

sure it is secure.

Polarized Plug Notice

This product is equipped with a polarized alternating current line
plug (a plug having one blade wider than the other). This plug
will fit into the power outlet only one way. This is a safety
feature. If you are unable to insert the plug fully into the outlet,
try reversing the plug. If the plug should still fail to fit, contact an
electrician to replace the obsolete outlet. Do not defeat the
purpose of the polarized plug.

To Operate

Plug cord into electrical outlet.

Power Switch

fig. 7

Push power switch to “ON” (I) position. 

Hose and Tool Installation

fig. 8

The flexible hose uses a Shurlock

®

locking system that

prevents hose removal unless intended. To install hose,
align “J” slot in hose coupling with tab inside the suction
port. Insert hose in port. Twist collar clockwise to lock
hose coupling in port. Twist counterclockwise and pull to
remove hose.

fig. 9

The adjustable extension wand and cleaning tools
supplied with your ORECK XL compact vacuum lock
together with friction. Twist and push to be sure they lock
tightly when installing. Twist and pull to remove.

E

N

G

L

I

S

H

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for BB1000

Page 1: ...800 989 4244 CANADA 1 800 393 8801 VISIT ONE OF OUR OVER 450 STORE LOCATIONS USA 1 800 989 3535 CANADA 1 888 676 7325 COMMERCIAL 1 800 242 1378 www oreck com www oreckcommercial com VISIT ONE OF OUR...

Page 2: ...1 7 8 9 11 12 18 19 20 13 2 3 1 4 5 14 15 16 17 10 6...

Page 3: ...ately 30 min the motor will have cooled and the cleaner will be ready to use Note The cleaner must remain unplugged for 30 minutes for motor to cool and system to reset E N G L I S H When using an ele...

Page 4: ...e damage caused by fire or act of God the use of voltages other than indicated on the serial number plate of this product or service of this product by other than ORECK or an ORECK Factory Authorized...

Page 5: ...ter and closing the cover until the top latch is locked NOTE It is recommended to replace the scent cartridge when the inner filter bag is replaced Replace the HEPA filter every 6 months Replace more...

Page 6: ...ur sales or purchase slip Should your ORECK appliance require warranty service in the U S A present this slip to the Authorized Service Center as your proof of purchase date or in Canada call customer...

Page 7: ...es d incendie d lectrocution et de blessure CONSIGNES DE S CURIT IMPORTANTES Ne jamais laisser l appareil branch sans surveillance L appareil doit tre d branch apr s chaque utilisation et avant toute...

Page 8: ...ne couvre pas les pi ces victimes d un accident d un usage abusif l utilisation commerciale d abus d une modification d une mauvaise utilisation de dommages caus s par un incendie ou une catastrophe...

Page 9: ...rieure du couvercle et en le refermant jusqu enclenchement de son verrouillage NOTE Il est recommand de remplacer la cartouche odorante au moment du remplacement du sac poussi re int rieur Remplacez l...

Page 10: ...in d une r paration sous garantie aux tats Unis pr sentez ce coupon au centre autoris de service apr s vente comme preuve d achat dat e Au Canada appelez le service la client le TOUTES LES AUTRES R PA...

Page 11: ...sicas incluyendo las siguientes LEA TODAS LAS INSTRUCCIONES ANTES DE USAR ESTA ASPIRADORA ADVERTENCIA Para reducir el riesgo de incendio descarga el ctrica o lesiones INSTRUCCIONES IMPORTANTES DE SEG...

Page 12: ...ial del abuso alteraci n uso indebido da os provocados por incendio o causas de fuerza mayor uso de voltajes diferentes a los indicados en la placa del n mero de serie de este producto o el servicio d...

Page 13: ...trucciones en la secci n C mo cambiar la bolsa de filtro fig 17 Saque el microfiltro viejo de la parte inferior dentro de la m quina Reemplace con un filtro nuevo NOTA En cada paquete de 12 bolsas de...

Page 14: ...omatizador fig 18 Para quitar la cubierta del filtro HEPA de la parte posterior de la m quina ejerza presi n en la ranura superior y pliegue hacia atr s la cubierta Levante la cubierta para retirarla...

Page 15: ...14...

Page 16: ...50 01 REV D 06 05 ECN R 8022 2005 Oreck Holdings LLC All rights reserved All word marks logos product configurations and registered trademarks are owned and used under the authority of Oreck Holdings...

Reviews: