20 |
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
(18.12.17) OC_RPG_L_BA_790038762_01_EN
Setup and assembly
RPG 4.5 (S), RPG 8.6
| Operating instructions
8.2
Inserting/replacing the clamping shells (not with RPG 4.5 S)
8.2.1
Inserting the lower clamping shell
1. Select the clamping shells according to the tube diameter.
2. Move the clamping lever to the open-position.
3. Place the lower clamping shell at the stop bolt (2).
4. Swivel the clamping shell around the stop bolt in the direction of the arrow until the unlock handle locks into place.
2
8.2.2
Inserting the upper clamping shell
1. Place the upper clamping shell at the stop bolt (3).
2. Swivel the clamping shell around the stop bolt in the direction of the arrow until the unlock handle locks into place.
3
8.2.3
Replacing the clamping shells
1. To replace the clamping shells, pull at the unlock handles.
2. Remove the upper and lower clamping shell.
Summary of Contents for RPG 4.5
Page 30: ......