Setup and assembly
8.3
Clamping the tube
WARNING
Flying parts/breaking tool!
Diverse physical injuries and material damage.
[
No
damaged or deformed cutting tools (MFW) should be used.
X
Firmly clamp the tube to be machined into the clamping unit.
X
Immediately replace worn-out tools.
X
Ensure that the cutting tools are correctly fitted.
X
The inner diameter of the clamping shells must be identical to the outer diameter of the tube to
be machined. The specific inner diameter is specified on the clamping shells. The outer diam-
eter of the tube must be determined.
X
Avoid tool breakage by ensuring low (measured) infeed (max. clamping thickness: 0.05 mm)
and correct setting of speed (see chap. 9.2, p. 26).
X
Check that the tool holder (WH) and multifunctional tool (MFW) are seated firmly, and tighten if
required.
8.3.1
RPG 4.5 and RPG 8.6
1. Open the clamping shells by shifting the clamping lever.
2. Insert the tube allowing it to have distance to the tool.
3. Clamp the tube in by means of the clamping lever.
4. Check the tube for correct clamping.
5. The tube can now be machined.
X
To release the tube from the machine, move the clamping lever to open it.
Summary of Contents for RPG 4.5