![background image](http://html.mh-extra.com/html/orbitalum/rpg-4-5/rpg-4-5_operating-instructions-manual_1648245023.webp)
(18.12.17) OC_RPG_L_BA_790038762_01_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
| 23
RPG 4.5 (S), RPG 8.6
| Operating instructions
Setup and assembly
8.3.4
Shifting the adjusting bolt
1. Loosen the clamping lever and remove the tube, if necessary.
2. Loosen the hexagon socket screw of the adjusting bolt using the Allan key.
3. Turn the adjusting bolt towards
+
or
–
.
4. Allow the pin to engage into the adjusting bolt and re-tighten the hexagon socket screw.
5. Now, the tube can be clamped in.