8.8.4
External remote control
Connecting a remote control
1. Remove the dummy plug in the remote control connection of the machine.
2. Connect the remote control.
1
1. EMERGENCY-STOP switch
2. Function keys
Fig. 24:
Remote control
8.8.5
External printer (A4)
USB connection: Can be selected freely on the rear of the machine.
Internal printer driver/character set: PCL 3
8.8.6
External monitor /HDMI
HDMI connection: Can be selected freely on the rear of the machine.
The machine display is not switched off when an additional monitor is connected.
8.9
Monitoring functions
8.9.1
General information
The machine monitors the following parameters:
• Gas quantity
• Coolant quantity
• Temperature of the power section
If the (permanently set) limit values are exceeded, the machine switches off automatically.
With the following parameters, the limit values (minimum and maximum values for warning and procedure abortion) are
set based on the procedure:
• Weld current
• Weld speed