ORBIMAT 180 SW
| Operating instructions
Operation
(17.09.18) OW_ORBIMAT_180SW_BA_850060202_00_EN
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
29
8. OPERATION
8.1
Auto programming
8.1.1
Setting parameters
1. Connect the weld head.
2. Switch on the machine.
The main menu appears in the display.
3. Select and highlight the "
Auto programming
" menu item.
The following display appears:
Field "....":
Return to main menu.
Fields "
Weld head model
" to "
Wall thickness
":
Parameter entry.
Field "
Wire feed
":
Welding with/without filler wire.
"
Calculate program
":
Calculation of the procedure with the entered parameters.
Fig. 7:
Sub menu – Auto programming
8.1.2
Configuring weld head
1. Select the "
Weld head
" field and briefly press the rotary knob.
The following display appears:
A list of the weld heads which can be used with this sys-
tem appears.
This system automatically detects the type of connected
head and offers it for selection first. In the example, this
is an OW 76S.
Fig. 8:
Selecting a weld head