![Orbit oceanTRX 4-500 Installation Manual Download Page 38](http://html1.mh-extra.com/html/orbit/oceantrx-4-500/oceantrx-4-500_installation-manual_1647858038.webp)
Compass Configuration
System Commissioning
4-14
OceanTRx™4-500 O3b System Installation Guide
3. Configure as follows:
Verify that Enable
is set to
Yes.
Under
Data Sharing
, set the following values:
o
For one of the MTSVLink (ACU), set as
Server
.
o
For the other MTSVLinks (ACU), set as
Client
.
Set Enable to
Yes
.
Set
COM Port Number
= 2 (RS422)
Set
Baud Rate –
according to compass baud rate (default 4800 bps).
Set
Format –
according to compass communication format (default = 8_NON_1).
Click
Apply
, verify Reading field displays a value and click
OK
.
4.4.1.3
Configuring the NMEA-0183 Compass Defaults
To configure to NMEA-0183 Compass Defaults
1. Using the MTSVLink, Open the
Config
menu and select Compass NMEA. The following
dialog appears.
Figure
4-13: NMEA-0183 Compass Defaults
2. Verify the following parameters are set accordingly:
Enable Checksum =
Yes
Under Enabled Devices, HE - Gyro, North Seeking =
Yes
Under Enabled Sentences, HDT - Heading, True =
Yes