OPTIMOD-FM DIGITAL
INTRODUCTION
1-21
tor shows the true peak level. It has an instantaneous attack time, and a release
time slow enough to allow the engineer to read the peak level easily. Fig. 1-1 shows
the relative difference between the absolute peak level, and the indications of a VU
meter and a PPM for a few seconds of music program.
Studio Line-up Levels and Headroom
ABSOLUTE PEAK
PPM
VU
Fig. 1-1: Absolute Peak Level, VU and PPM Reading
The studio engineer is primarily concerned with calibrating the equipment to pro-
vide the required input level for proper operation of each device, and so that all de-
vices operate with the same input and output levels. This facilitates patching devices
in and out without recalibration.
For line-up, the studio engineer uses a calibration tone at a studio standard level,
commonly called line-up level, reference level, or operating level. Metering at the
studio is by a VU meter or PPM (Peak Program Meter). As discussed above, the VU or
PPM indication under-indicates the true peak level. Most modern studio audio de-
vices have a clipping level of no less than +21 dBu, and often +24 dBu or more. So
the studio standardizes on a maximum program indication on the meter that is
lower than the clipping level, so those peaks that the meter does not indicate will
not be clipped. Line-up level is usually at this same maximum meter indication. In fa-
cilities that use VU meters, this level is usually at 0VU, which corresponds to the stu-
dio standard level, typ4 or +8 dBu.
For facilities using +4 dBu standard level, instantaneous peaks can reach +18 dBu or
higher (particularly if the operator overdrives the console or desk). Older facilities
with +8 dBu standard level and equipment that clips at +18 or +21 dBu will experi-
ence noticeable clipping on some program material.
In facilities that use the BBC-standard PPM, maximum program level is usually PPM4
for music, PPM6 for speech. Line-up level is usually PPM4, which corresponds to +4
dBu. Instantaneous peaks will reach +17 dBu or more on voice.
In facilities that use PPMs that indicate level directly in dBu, maximum program and
line-up level is often +6 dBu. Instantaneous peaks will reach +11 dBu or more.
Summary of Contents for OPTIMOD-FM 8600Si
Page 1: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Page 7: ...Operating Manual OPTIMOD FM 8600Si Digital Audio Processor Version 2 5 Software...
Page 56: ......
Page 255: ...OPTIMOD FM DIGITAL OPERATION 3 89...
Page 272: ......
Page 328: ......
Page 330: ...6 28 TECHNICAL DATA ORBAN MODEL 8600Si CONTROL BOARD PARTS LOCATOR...
Page 354: ...6 52 TECHNICAL DATA ORBAN MODEL 8600Si...